Anaesthesia and intensive care
-
Anaesth Intensive Care · Aug 2004
Serum procalcitonin and C-reactive protein as markers of sepsis and outcome in patients with neurotrauma and subarachnoid haemorrhage.
This prospective study evaluated serum procalcitonin (PCT) and C-reactive protein (CRP) as markers for systemic inflammatory response syndrome (SIRS)/sepsis and mortality in patients with traumatic brain injury and subarachnoid haemorrhage. Sixty-two patients were followed for 7 days. Serum PCT and CRP were measured on days 0, 1, 4, 5, 6 and 7. ⋯ This is in part because baseline PCT elevation seemed to correlate with severity of injury. Only a small proportion of patients developed sepsis, thus necessitating a larger sample size to demonstrate the diagnostic usefulness of serum PCT as a marker of sepsis. Further clinical trials with larger sample sizes are required to confirm any potential role of PCT as a sepsis and outcome indicator in patients with head injuries or subarachnoid haemorrhage.
-
Amiodarone, a class III antiarrhythmic, has been widely used to treat both ventricular and supraventricular arrhythmias. Despite the multitude of side-effects seen with this drug, no case of amiodarone anaphylaxis (confirmed by mast cell tryptase levels and skin testing) has been reported in the medical literature. We report a case of anaphylaxis to intravenous amiodarone in a 77-year-old patient.
-
Anaesth Intensive Care · Aug 2004
Effect of laryngoscopy and tracheal intubation on pulse pressure and influence of age on this response.
The study objective was to measure the change in pulse pressure associated with laryngoscopy and tracheal intubation and to relate these changes to trends in systolic, diastolic and mean blood pressure. The rationale was that the rise in systolic and diastolic blood pressure may be disproportionate and may result in either increase or decrease in pulse pressure. We also looked at the influence of age on this response. ⋯ No pulse pressure change occurred in the young group despite of a significant increase in both systolic and diastolic blood pressures. The middle aged group showed an average rise of +18 mm of Hg in pulse pressure (taken at 1 minute post-intubation) compared to the baseline measurement (P<0.0001). These changes in pulse pressure during anaesthesia may indicate an additional pulsatile stress in vulnerable patients in addition to the changes associated with resistance alone and need to be studied further.
-
Entropy is a new EEG based technology developed as a measure of depth of anaesthesia. The Entropy algorithm quantifies the degree of disorder in the EEG. During anaesthesia the disorder of the EEG, or entropy, falls. ⋯ The correlation was less for infants. This study demonstrates that, in children, Entropy is lower during anaesthesia when compared to awake values. Further evaluation in the paediatric population is worthwhile.