Anaesthesia and intensive care
-
Anaesth Intensive Care · Nov 2016
ReviewCurrent limitations of the assessment of haemostasis in adult extracorporeal membrane oxygenation patients and the role of point-of-care testing.
Haemostatic perturbations are commonly seen in extracorporeal membrane oxygenation (ECMO) patients and remain a clinical challenge, contributing significantly to morbidity and mortality. The approach to anticoagulation monitoring and the management of bleeding varies considerably across ECMO centres. Routine laboratory tests have their limitations in terms of turnaround time and specificity of information provided. ⋯ It is also possible to obtain qualitative information on platelet function from these tests. Furthermore, the ability to incorporate these results into a goal-directed algorithm to manage bleeding with targeted transfusion strategies appears particularly attractive and cost effective. Further studies are required to evaluate the utility of POCT to optimise bleeding and anticoagulation management in these complex patients.
-
Anaesth Intensive Care · Sep 2016
ReviewSpeckle tracking echocardiography in the critically ill: enticing research with minimal clinical practicality or the answer to non-invasive cardiac assessment?
Echocardiography is developing rapidly. Speckle tracking echocardiography is the latest semi-automatic tool that has potential to quantitatively describe cardiac dysfunction that may be unrecognised by conventional echocardiography. It is a non-Doppler, angle-independent, feasible and reproducible method to evaluate myocardial function in both non-critically ill and critically ill populations. ⋯ We should be cautious in accepting that the latest software used in cardiology cohorts will automatically be the answer in the critically ill. Even with these limitations the technology is enticing and results fascinating. We are uncovering previously undescribed dysfunction and although it currently is essentially a research-based activity, there is great promise as a clinical tool as echocardiography analysis becomes more automated, and potentially speckle tracking echocardiography could help describe cardiac function in critical illness more accurately than is possible with current techniques.
-
Anaesth Intensive Care · Sep 2016
Review Meta AnalysisDoes objective measurement of tracheal tube cuff pressures minimise adverse effects and maintain accurate cuff pressures? A systematic review and meta-analysis.
Correct inflation pressures of the tracheal cuff are recommended to ensure adequate ventilation and prevent aspiration and adverse events. However there are conflicting views on which measurement to employ. The aim of this review was to examine whether adjustment of cuff pressure guided by objective measurement, compared with subjective measurement or observation of the pressure value alone, was able to prevent patient-related adverse effects and maintain accurate cuff pressures. ⋯ These included cough at two hours (odds ratio [OR] 0.42, confidence interval [CI] 0.23 to 0.79, P=0.007), hoarseness at 24 hours (OR 0.49, CI 0.31 to 0.76, P <0.002), sore throat (OR 0.73, CI 0.54 to 0.97, P <0.03), lesions of the trachea and incidences of silent aspiration (P=0.001), as well as maintaining accurate cuff pressures (Hedges' g 1.61, CI 2.69 to 0.53, P=0.003). Subjective measurement to guide adjustment or observation of the pressure value alone may lead to patient-related adverse effects and inaccuracies. It is recommended that an objective form of measurement be used.
-
Anaesth Intensive Care · Sep 2016
Review Meta AnalysisDoes objective measurement of tracheal tube cuff pressures minimise adverse effects and maintain accurate cuff pressures? A systematic review and meta-analysis.
Correct inflation pressures of the tracheal cuff are recommended to ensure adequate ventilation and prevent aspiration and adverse events. However there are conflicting views on which measurement to employ. The aim of this review was to examine whether adjustment of cuff pressure guided by objective measurement, compared with subjective measurement or observation of the pressure value alone, was able to prevent patient-related adverse effects and maintain accurate cuff pressures. ⋯ These included cough at two hours (odds ratio [OR] 0.42, confidence interval [CI] 0.23 to 0.79, P=0.007), hoarseness at 24 hours (OR 0.49, CI 0.31 to 0.76, P <0.002), sore throat (OR 0.73, CI 0.54 to 0.97, P <0.03), lesions of the trachea and incidences of silent aspiration (P=0.001), as well as maintaining accurate cuff pressures (Hedges' g 1.61, CI 2.69 to 0.53, P=0.003). Subjective measurement to guide adjustment or observation of the pressure value alone may lead to patient-related adverse effects and inaccuracies. It is recommended that an objective form of measurement be used.
-
Vitamin B12 is an essential micronutrient, as humans have no capacity to produce the vitamin and it needs to be ingested from animal proteins. The ingested Vitamin B12 undergoes a complex process of absorption and assimilation. Vitamin B12 is essential for cellular function. ⋯ Low levels of Vitamin B12 may also be an independent risk factor for coronary artery disease. High levels of Vitamin B12 are associated with inflammation and represent a poor outlook for critically ill patients. Treatment of Vitamin B12 deficiency is simple, but may be lifelong.