Perfusion
-
As a result of improvements in early outcomes, long-term neurologicalal outcomes are becoming a major issue in pediatric cardiac surgery. The mechanisms of brain injury are numerous, but a vast majority of injuries are impervious to therapy and only a few are modifiable. The quality of perfusion during cardiac surgery is a modifiable factor and cerebral monitoring during bypass is the way to assess the quality of intra-operative cerebral perfusion. ⋯ The clinical relevance of cerebral oxymetry is needed before the use of NIRS as a decision making tool. Multimodal brain monitoring with NIRS, trans-cranial Doppler and electroencephalogram are currently under way in several pediatric centers. The benefit of this time-consuming and expensive monitoring system has yet to be demonstrated.
-
Mild to moderate systemic hypothermia is commonly used as a cerebral protective strategy during adult cardiac surgery. The benefits of this strategy for routine cardiac surgery have been questioned and the adverse effects of hyperthermia demonstrated. The purpose of the present study was to examine current temperature management and monitoring practices during adult cardiac surgery using CPB in Canada. ⋯ Contemporary management of adult cardiac surgery under CPB still involves induction of mild to moderate systemic hypothermia. Significant practice variation exists across the country with respect to target temperatures for cooling and rewarming, as well as the site for temperature monitoring. This probably reflects the lack of definitive evidence. There is a need for well-conducted clinical trials to provide more robust evidence regarding temperature management.
-
Volatile anaesthetic agents are widely used for maintenance of anaesthesia in all kinds of surgical procedures. Despite the implementation of measures such as adequate ventilation of the operating room and the use of efficient scavenging systems, concern remains about the risks for occupational exposure, especially in situations associated with an increased risk of anaesthetic gas waste, such as with the use of volatile anaesthetic agents on cardiopulmonary bypass. The present contribution reports the results of a preliminary safety assessment involving measurements of sevoflurane concentrations in the ambient air of a cardiac surgery operating room. ⋯ The concentrations were measured on-line using a photoacoustic infrared spectrometer. Mean sevoflurane waste concentrations remained consistently below the recommended target value of 4.68 ppm throughout the observation period at the different measurement sites. These results indicate that, with the use of sevoflurane on cardiopulmonary bypass, the recommended levels for occupational exposure are not exceeded, provided adequate operation room ventilation and waste gas scavenging is performed.
-
The new Perfusion Simulation Center at the Medical University of South Carolina provides a new level of high fidelity simulation training for perfusion students. A key component is the Orpheus Perfusion Simulator which is a computer-driven simulator integrated with the mechanical connections of the heart-lung machine to allow for real time operative procedures and perfusion incidents. Due to the ability to consistently reproduce cardiac surgical scenarios, it is possible to develop both basic perfusion skills as well as advanced emergency skills more effectively than with animal models. ⋯ In the second set of scenarios, logical, clear-thinking, and attentive were the most common personality traits observed of the effective team members. Simulation has become an invaluable tool for perfusion education and the goal of improving patient safety during cardiopulmonary bypass. The opportunities for advanced training in the perfusion simulation environment will certainly expand in the future.
-
Comparative Study Clinical Trial
Retrograde autologous priming reduces transfusion requirements in coronary artery bypass surgery.
The hypothesis was tested whether retrograde autologous priming (RAP) of the cardiopulmonary bypass system, compared to a standard primed system (NON-RAP group), results in less haemodilution and less transfusion of packed red blood cells. Retrospectively, data was collected from the medical charts of one hundred patients undergoing elective coronary artery bypass grafting using cardiopulmonary bypass. Fifty patients where RAP was used have been compared to fifty patients using NON-RAP. ⋯ In the NON-RAP group, 26% of the patients received packed red cells in contrast to 6% in the RAP group (p<0.012). A positive association was found between RAP and less transfusion of packed red blood cells (p<0.012). In conclusion, retrograde autologous priming, reducing the prime volume of the cardiopulmonary bypass system, causes less haemodilution and reduces intraoperative transfusion of packed red blood cells.