Journal of clinical anesthesia
-
Multicenter Study
Peripheral perfusion index stratifies risk in patients with intraoperative anemia: A multicentre cohort study.
Evidence for red blood cell (RBC) transfusion thresholds in the intraoperative setting is limited, and current perioperative recommendations may not correspond with individual intraoperative physiological demands. Hemodynamics relevant for the decision to transfuse may include peripheral perfusion index (PPI). The objective of this prospective study was to assess the associations of PPI and hemoglobin levels with the risk of postoperative morbidity and mortality. ⋯ High PPI in acute surgical patients who also presents with anemia was associated with a significantly better outcome when compared with patients with both low PPI and anemia. PPI should therefore be further investigated as a potential parameter to guide intraoperative RBC transfusion therapy.
-
Randomized Controlled Trial
Effect of postoperative intermittent boluses of subcostal quadratus lumborum block on pulmonary function recovery and analgesia after gastrectomy: a randomized controlled clinical trial.
Following the gastrectomy, the reduction in pulmonary function is partly attributed to postoperative pain. Subcostal quadratus lumborum block (QLB) has recently emerged as a promising component in multimodal analgesia. We aimed to assess the impact of intermittent boluses of subcostal QLB on pulmonary function recovery and analgesic efficacy after gastrectomy. ⋯ Postoperative intermittent boluses of subcostal QLB did not confer advantages in terms of the preservation of FEV1 or pain scores on coughing 24 h after gastrectomy. However, notable effects were observed in analgesia at rest and FVC recovery.
-
To examine the effects of a non-reactive carbon dioxide absorbent (AMSORB® Plus) versus a traditional carbon dioxide absorbent (Medisorb™) on the FGF used by anesthesia providers and an electronic educational feedback intervention using Carestation™ Insights (GE HealthCare) on provider-specific change in FGF. ⋯ This study showed that introducing a non-reactive absorbent did not significantly alter FGF. Using environmentally oriented electronic feedback relying on data analytics did not result in significantly reduced provider-specific FGF.
-
Randomized Controlled Trial Comparative Study
Comparative effects of variable versus conventional volume-controlled one-lung ventilation on gas exchange and respiratory system mechanics in thoracic surgery patients: A randomized controlled clinical trial.
Mechanical ventilation with variable tidal volumes (V-VCV) has the potential to improve lung function during general anesthesia. We tested the hypothesis that V-VCV compared to conventional volume-controlled ventilation (C-VCV) would improve intraoperative arterial oxygenation and respiratory system mechanics in patients undergoing thoracic surgery under one-lung ventilation (OLV). ⋯ In thoracic surgery patients under OLV, V-VCV did not improve oxygenation or respiratory system mechanics compared to C-VCV. Ethical Committee: EK 420092019.
-
Randomized Controlled Trial
One-lung ventilation with fixed and variable tidal volumes on oxygenation and pulmonary outcomes: A randomized trial.
Test the hypothesis that one-lung ventilation with variable tidal volume improves intraoperative oxygenation and reduces postoperative pulmonary complications after lung resection. ⋯ One-lung ventilation with variable tidal volume does not meaningfully improve intraoperative oxygenation, and does not reduce postoperative pulmonary complications.