Journal of magnetic resonance imaging : JMRI
-
J Magn Reson Imaging · May 2014
Functional magnetic resonance cholangiography enhanced with Gd-EOB-DTPA: effect of liver function on biliary system visualization.
To evaluate effect of liver function on biliary system visualization using gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance cholangiography (CE-MRC). ⋯ Different liver function according to Child-Pugh classification significantly affects biliary system visualization of Gd-EOB-DTPA CE-MRC.
-
J Magn Reson Imaging · May 2014
Comparative StudyOptimized simultaneous ASL and BOLD functional imaging of the whole brain.
To compare a double-excitation combined arterial-spin labeling/blood-oxygenation level dependent (ASL/BOLD) functional imaging method to a double-echo method. ASL provides a useful complement to standard BOLD functional imaging, to map effects of cerebral hemodynamics. Whole-brain imaging is necessary to properly characterize large functional networks. A challenge of whole-brain ASL/BOLD is that images for ASL functional contrast must be acquired before significant longitudinal relaxation of the inverted spins occurs; however, a longer echo time (TE) is required for optimal BOLD functional contrast, lengthening the acquisition time. Thus, existing combined ASL/BOLD studies have only partial-brain coverage. ⋯ Our method simultaneously optimizes ASL and BOLD acquisitions for CNR while economizing acquisition time.
-
J Magn Reson Imaging · May 2014
Comparative StudyVisualization of acute focal lesions in rats with experimental autoimmune encephalomyelitis by magnetic nanoparticles, comparing different MRI sequences including phase imaging.
To compare the sensitivity and specificity of phase imaging (PI) with other magnetic resonance imaging (MRI) methods in lesion detection in rats with experimental autoimmune encephalomyelitis (EAE), as an animal model for multiple sclerosis (MS). ⋯ The diagnostic use of PI without VSOP as contrast agent to detect lesions is not recommended at field strength of 4.7T or lower.
-
J Magn Reson Imaging · May 2014
Optimization of b-value distribution for biexponential diffusion-weighted MR imaging of normal prostate.
To determine the optimal b-value distribution for biexponential diffusion-weighted imaging (DWI) of normal prostate using both a computer modeling approach and in vivo measurements. ⋯ The optimal b-value distribution was found to be a clustered distribution with b-values concentrated in the low, mid, and high ranges and was shown to improve the estimation quality of biexponential DWI parameters of in vivo experiments.
-
J Magn Reson Imaging · May 2014
Rapid multicomponent T2 analysis of the articular cartilage of the human knee joint at 3.0T.
To determine the feasibility of using multicomponent-driven equilibrium single-shot observation of T1 and T2 (mcDESPOT) for evaluating the human knee joint at 3.0T and to investigate depth-dependent and regional-dependent variations in multicomponent T2 parameters within articular cartilage. ⋯ Multicomponent T2 parameters of the articular cartilage of the human knee joint can be measured at 3.0T using mcDESPOT and show depth-dependent and regional-dependent variations.