Journal of magnetic resonance imaging : JMRI
-
J Magn Reson Imaging · Mar 2005
An automated algorithm for combining multivoxel MRS data acquired with phased-array coils.
To develop a fully automated algorithm for combining multivoxel magnetic resonance spectroscopy (MRS) data acquired with a phased-array coil. ⋯ The method described in this report provides a means for employing phased-array coils in MRS with the same advantages as those found in MRI.
-
J Magn Reson Imaging · Mar 2005
Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study.
To optimize and assess the feasibility of a single-shot black-blood T2-weighted spin-echo echo-planar imaging (SSBB-EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2-weighted turbo spin-echo (TSE) sequence. ⋯ Optimized SSBB-EPI with SENSE proved to be feasible in patients, and the overall image quality and SNR of the liver were comparable to those achieved with the standard respiratory-triggered T2-weighted TSE sequence.
-
J Magn Reson Imaging · Mar 2005
Comparative StudyMultislice MR first-pass myocardial perfusion imaging: impact of the receiver coil array.
To compare a new 12-element body phased-array coil with a conventional four-element surface receiver coil array to provide increased signal-to-noise ratios (SNRs) for cardiac steady state free precession (SSFP) perfusion imaging. ⋯ The 12-element coil array provides higher SNR, but these improvements come with trade-offs in image homogeneity. Increased SNR translates into higher semiquantitative perfusion values and offers the potential for improved detection of perfusion defects.
-
J Magn Reson Imaging · Feb 2005
Comparative StudyDisparity of activation onset in sensory cortex from simultaneous auditory and visual stimulation: Differences between perfusion and blood oxygenation level-dependent functional magnetic resonance imaging.
To compare the temporal behaviors of perfusion and blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) in the detection of timing differences between distinct brain areas, and determine potential latency differences between stimulus onset and measurable fMRI signal in sensory cortices. ⋯ The greater temporal variability between brain areas detected with BOLD could result from differences in the venous contributions to the signal. The results suggest that perfusion methods may provide more accurate timing information of neuronal activities than BOLD-based imaging.
-
J Magn Reson Imaging · Feb 2005
Interstudy reproducibility of three-dimensional volume-selective fast spin echo magnetic resonance for quantifying carotid artery wall volume.
To assess the interstudy reproducibility of a three-dimensional volume-selective, fast spin echo (FSE) magnetic resonance technique for the assessment of carotid artery wall volume, which is a marker for total carotid plaque volume. ⋯ Volumetric analysis with CMR of carotid artery plaques using a three-dimensional volume-selective FSE is efficient with good interstudy reproducibility, and is well suited for longitudinal studies of progression of carotid atheroma with reasonable sample sizes.