Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology
-
Ultrasound Obstet Gynecol · Nov 2017
Review Meta AnalysisRisk of Cesarean scar defect following single- vs double-layer uterine closure: systematic review and meta-analysis of randomized controlled trials.
There is a growing body of evidence that suggests that the surgical technique for uterine closure following Cesarean delivery influences the healing of the Cesarean scar, but there is still no consensus on the optimal technique. The aim of this systematic review and meta-analysis was to compare the effect of single- vs double-layer uterine closure on the risk of uterine scar defect. ⋯ Single- and double-layer closure of the uterine incision following Cesarean delivery are associated with a similar incidence of Cesarean scar defects, as well as uterine dehiscence and rupture in a subsequent pregnancy. However, the quality level of summary estimates, as assessed by GRADE, was low, indicating that the true effect may be, or is even likely to be, substantially different from the estimate of the effect. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
-
Ultrasound Obstet Gynecol · Nov 2017
Review Meta AnalysisRisk of Cesarean scar defect following single- vs double-layer uterine closure: systematic review and meta-analysis of randomized controlled trials.
There is a growing body of evidence that suggests that the surgical technique for uterine closure following Cesarean delivery influences the healing of the Cesarean scar, but there is still no consensus on the optimal technique. The aim of this systematic review and meta-analysis was to compare the effect of single- vs double-layer uterine closure on the risk of uterine scar defect. ⋯ Single- and double-layer closure of the uterine incision following Cesarean delivery are associated with a similar incidence of Cesarean scar defects, as well as uterine dehiscence and rupture in a subsequent pregnancy. However, the quality level of summary estimates, as assessed by GRADE, was low, indicating that the true effect may be, or is even likely to be, substantially different from the estimate of the effect. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
-
Ultrasound Obstet Gynecol · Nov 2017
Review Meta AnalysisCerclage for sonographic short cervix in singleton gestations without prior spontaneous preterm birth: systematic review and meta-analysis of randomized controlled trials using individual patient-level data.
The aim of this systematic review and meta-analysis was to quantify the efficacy of cervical cerclage in preventing preterm birth (PTB) in asymptomatic singleton pregnancies with a short mid-trimester cervical length (CL) on transvaginal sonography (TVS) and without prior spontaneous PTB. ⋯ In singleton gestations without prior spontaneous PTB but with TVS-CL < 25 mm in the second trimester, cerclage does not seem to prevent preterm delivery or improve neonatal outcome. However, in these pregnancies, cerclage seems to be efficacious at lower CLs, such as < 10 mm, and when tocolytics or antibiotics are used as additional therapy, requiring further studies in these subgroups. Given the low quality of evidence, further well-designed RCTs are needed to confirm the findings of this study. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
-
Ultrasound Obstet Gynecol · Nov 2017
Review Meta AnalysisCerclage for sonographic short cervix in singleton gestations without prior spontaneous preterm birth: systematic review and meta-analysis of randomized controlled trials using individual patient-level data.
The aim of this systematic review and meta-analysis was to quantify the efficacy of cervical cerclage in preventing preterm birth (PTB) in asymptomatic singleton pregnancies with a short mid-trimester cervical length (CL) on transvaginal sonography (TVS) and without prior spontaneous PTB. ⋯ In singleton gestations without prior spontaneous PTB but with TVS-CL < 25 mm in the second trimester, cerclage does not seem to prevent preterm delivery or improve neonatal outcome. However, in these pregnancies, cerclage seems to be efficacious at lower CLs, such as < 10 mm, and when tocolytics or antibiotics are used as additional therapy, requiring further studies in these subgroups. Given the low quality of evidence, further well-designed RCTs are needed to confirm the findings of this study. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
-
Ultrasound Obstet Gynecol · Oct 2017
ReviewQuality of reporting of diagnostic accuracy studies on pelvic floor three-dimensional transperineal ultrasound: a systematic review.
In recent years, a large number of studies have been published on the clinical relevance of pelvic floor three-dimensional (3D) transperineal ultrasound. Several studies compare sonography with other imaging modalities or clinical examination. The quality of reporting in these studies is not known. The objective of this systematic review was to determine the compliance of diagnostic accuracy studies investigating pelvic floor 3D ultrasound with the Standards for Reporting of Diagnostic Accuracy (STARD) guidelines. ⋯ The overall compliance with reporting guidelines of diagnostic accuracy studies on pelvic floor 3D transperineal ultrasound is relatively good compared with other fields of medicine. However, specific checklist items require more attention when reported. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.