ASAIO journal : a peer-reviewed journal of the American Society for Artificial Internal Organs
-
Human leukocyte antigen (HLA) sensitization of pediatric heart recipients increases their risk of rejection and graft loss. As more children are placed on mechanical circulatory support (MCS) as a bridge to transplant, the risk factors for development of sensitization warrant further study. A single-center retrospective review of 36 children who received MCS identified 22 patients supported with either extracorporeal membrane oxygenation (ECMO) (n = 15) or ECMO-ventricular assist device (VAD) (n = 7) with paired (pre-MCS/post-MCS) panel reactive antibodies (PRA) or only negative post-MCS PRAs. ⋯ By multivariable analysis, the association of sensitization with older age at MCS (p = 0.076) and history of homograft (p = 0.064) approached significance. Pediatric patients supported with MCS are at low risk of developing HLA sensitization. Diagnosis, MCS duration, and volume of transfused blood products do not appear to be associated with HLA sensitization, but there is a suggestion of an association with older age at MCS and history of a homograft.
-
Percutaneous continuous-flow (CF) micro axial blood pumps, like the Impella 5.0, are commonly used for short-term (ST) mechanical circulatory support in patients with acute decompensated heart failure. The Impella device often serves as a bridge to implantation of a long-term (LT) CF left ventricular assist device (CF-LVAD), such as the centrifugal-flow HeartWare (HVAD). All patients supported with axial CF-LVADs develop acquired von Willebrand syndrome (AVWS) as a result of mechanical shear stress. ⋯ Bleeding events associated with AVWS have been reported in patients supported with LT CF-LVADs; however, the relation between early perioperative bleeding complications and AVWS remains poorly characterized in ST CF-LVADs. We sought to describe the relation between the development of AVWS and excessive intraoperative bleeding in a patient who was sequentially bridged with an ST micro axial device to a LT centrifugal CF-LVAD. This case highlights the importance of monitoring these hemostatic changes when bridging to LT CF-LVADs.
-
It has been suggested that pulsatile blood flow is superior to continuous flow (CF) in cardiopulmonary bypass (CPB). However, adoption of pulsatile flow (PF) technology has been limited because of practicality and complexity of creating a consistent physiologic pulse. A pediatric pulsatile rotary ventricular pump (PRVP) was designed to address this problem. ⋯ Pressure and flow waveforms demonstrated significant pulsatility in the PRVP setup compared with CF at all tested conditions. Measurement of hemodynamic energy data, including the percentage pulsatile energy and the surplus hydraulic energy, also revealed a significant increase in pulsatility with the PRVP (p < 0.001). The PRVP creates physiologically significant PF, similar to the pulsatility of a native heart, and has the potential to be easily implemented in pediatric CPB.
-
iLA Activve is a new minimally invasive device for extracorporeal CO2 removal (ECCO2-R) using a miniaturized pump, a special gas exchange membrane, and a double-lumen cannula. We retrospectively analyzed our experiences in 12 patients with hypercapnic respiratory failure undergoing ECCO2-R. Indication for ECCO2-R was hypercapnia due to terminal lung failure during bridging to lung transplantation, pneumonia, and chronic obstructive lung disease or asthma. ⋯ Invasiveness of ventilation could be reduced. Additional severe impairment of oxygenation and prolonged mechanical ventilation before ECCO2-R are factors of adverse prognosis. The use of ECCO2-R should be thoroughly reconsidered in these cases.
-
Ventricular arrhythmias (VAs) are common after implantation of a left ventricular assist device (LVAD) and in a subset of patients may be refractory to medication. Morbidity from VA in this population includes right ventricular failure (RVF). We sought to evaluate the efficacy of catheter ablation for VA in patients with LVAD. ⋯ Although the majority had reduction in VA frequency, recurrent VAs were observed in six patients (85.7%). One patient (14.3%) experienced a bleeding complication after the procedure. For patients with a high VA burden after LVAD implantation, VT ablation is safe and feasible, but VA frequently recurs.