European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
A high rate of pseudarthrosis and a high overall rate of implant migration requiring surgical revision has been reported following posterior lumbar interbody fusion using BAK threaded cages. The high rate of both pseudarthrosis and implant migration may be due to poor fixation of the implant. The purpose of this study was to analyse the motion of threaded cages in posterior lumbar interbody fusion. ⋯ Motion of the implants was not seen in compression. In torsion, a rolling motion was noted, with a range of motion of 10.6 degrees around the central axis of the implant when left/right torsion (25 Nm) was applied. The way the implants move within the segment may be due to their special shape: the thread of the implants can not prevent the BAK cages rolling within the disc space.