European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Comparative Study
The reliability of the Vernon and Mior neck disability index, and its validity compared with the short form-36 health survey questionnaire.
Prospective single cohort study. To evaluate the NDI by comparison with the SF36 health Survey Questionnaire. The NDI is a simple ten-item questionnaire used to assess patients with neck pain. ⋯ The test-retest reliability of the NDI was high (intra-class correlation 0.93, 95% confidence limits 0.86-0.97) and comparable with the best values found for SF36. The correlations between NDI and SF36 domains ranged from -0.45 to -0.74 (all with P < 0.001). We have shown that the NDI has good reliability and validity and that it compares well with the SF36 in the spinal surgery out patient setting.
-
Transforaminal lumbar interbody fusion (TLIF) is an effective treatment for patients with degenerative spondylolisthesis and degenerative disc disease. Opposite side radiculopathy after the TLIF procedure has been recognized in this institution but has not been addressed in the literature. ⋯ We believe that this complication is related to asymptomatic stenosis on the contralateral side that is unmasked by the increased lordosis of the TLIF. The authors recommend increasing both disc height and foraminal height when choosing an interbody graft, and possibly decompressing the opposite foramen when preoperative MRI demonstrates foraminal stenosis.
-
Several types of posterior approaches have been adopted for occipitocervical fusion. Prior to this study, Foerater et al. in 1927 used a fibular strut graft in the site between the occiput and the lower cervical spine to achieve fusion. Since then, various techniques including wrings, Hartshill loop, AO reconstructive plate, and AXIS occipital plate were described and used widely. ⋯ The mean thickness for safe screw insertion ranged from 5.73 to 14.14 mm. A total of 22 intraocciput screws parallel to diploic bone were placed precisely, without injury to the cerebral and inner occipital venous sinus. The results confirm that occiput is available for holding intraocciput screw paralleling to diploic bone.
-
Case Reports
Concomitant fracture of bilateral occipital condyle and inferior clivus: what is the mechanism of injury?
With the routine use of multi-slice high resolution computed tomography, increasing number of occipital condyle fractures have been reported in the last decade. The authors report a very rare case of bilateral occipital condyle fracture complicated by the fracture of the inferior clivus and discuss the possible mechanisms of injury.
-
Although extravasations of polymethylmetharylate during percutaneous vertebroplasty are usually of little clinical consequence, surgical decompression is occasionally required if resultant neurologic deficits are severe. Surgical removal of epidural polymethylmetharylate is usually necessary to achieve good neurologic recovery. Because mobilizing the squeezed spinal cord in a compromised canal can cause further deterioration, attempts to remove epidural polymethylmetharylate in the thoracic region need special consideration. ⋯ Spinal stability was reconstructed by supplemental spinal instrumentation and intertransverse arthrodesis with banked cancellous allografts. Myelopathy and radicular pain gradually resolved after decompression surgery. The patient was free of sensory abnormality and regained satisfactory ambulation two years after surgical decompression.