European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Comparative Study
Evaluation of ABM/P-15 versus autogenous bone in an ovine lumbar interbody fusion model.
A prospective, randomized study was performed in an ovine model to compare the efficacy of an anorganic bovine-derived hydroxyapatite matrix combined with a synthetic 15 amino acid residue (ABM/P-15) in facilitating lumbar interbody fusion when compared with autogenous bone harvested from the iliac crest. P-15 is a biomimetic to the cell-binding site of Type-I collagen for bone-forming cells. When combined with ABM, it creates the necessary scaffold to initiate cell invasion, binding, and subsequent osteogenesis. ⋯ Clinical CT scan analysis showed that all autograft and ABM/P-15 treated levels had radiographically fused outside of the rings at the 3-month study time point. Although the clinical CT scans of the autograft treatment group showed significantly better fusion within the PEEK rings than ABM/P-15 at 3 months, micro-CT scans, clinical CT scans, and histomorphometric analyses showed there were no statistical differences between the two treatment groups at 6 months. Thus, ABM/P-15 was as successful as autogenous bone graft in producing lumbar spinal fusion in an ovine model, and it should be further evaluated in clinical studies.
-
Linezolid belongs to a new class of synthetic antimicrobial agent that is effective for a variety of methicillin-resistant Staphylococcus aureus (MRSA) infections including bone and joint MRSA infections, but the effectiveness of linezolid for the treatment of MRSA spine infection remains controversial. In this study, we investigated the diffusion of linezolid or vancomycin into normal rabbit spinal tissues to determine the adequacy of linezolid for the treatment of spinal infection. ⋯ The penetration efficacy of linezolid into the bone marrow and iliopsoas muscle (88 and 84%, respectively), however, was higher than that of vancomycin (67 and 9%, respectively). These results suggest that linezolid is inadequate for the treatment of spine infection limited to the intervertebral disc, but may be effective for the treatment of infection extending into the muscle and bone marrow, such as in vertebral osteomyelitis, iliopsoas abscess, and postsurgical infection.
-
Transpedicular fixation can be challenging in the osteoporotic spine as reduced bone mineral density compromises the mechanical stability of the pedicle screw. Here, we sought to investigate the biomechanical and histological properties of stabilization of expandable pedicle screw (EPS) in the osteoporotic spine in sheep. EPSs and standard pedicle screws, SINO screws, were inserted on the vertebral bodies in four female ovariectomized sheep. ⋯ Histologically, newly formed bone tissues grew into the center of EPS and were in close contact with the EPS. Our results show that the EPS demonstrates improved biomechanical and histological properties over the standard screw in the osteoporotic spine. The EPS may be of value in treating patients with osteoporosis and warrants further clinical studies.
-
Randomized Controlled Trial
Dynamic stabilization adjacent to single-level fusion: part II. No clinical benefit for asymptomatic, initially degenerated adjacent segments after 6 years follow-up.
Progression of degeneration is often described in patients with initially degenerated segment adjacent to fusion (iASD) at the time of surgery. The aim of the present study was to compare dynamic fixation of a clinically asymptomatic iASD, with circumferential lumbar fusion alone. 60 patients with symptomatic degeneration of L5/S1 or L4/L5 (Modic ≥ 2°) and asymptomatic iASD (Modic = 1°, confirmed by discography) were divided into two groups. 30 patients were treated with circumferential single-level fusion (SLF). In dynamic fixation transition (DFT) patients, additional posterior dynamic fixation of iASD was performed. ⋯ Clinical scores were equal in patients with PASD and/or radiologically adverse events. We do not recommend dynamically fixating the adjacent segment in patients with clinically asymptomatic iASD. The lower number of PASD with dynamic fixation was accompanied by a high number of implant failures and a shift of PASD to the superior segment.