European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
To investigate intra- and inter-rater reliability of the ultrasound measurement of transversus abdominis (TrA) thickness and thickness change (difference between thickness at rest and during contraction) in asymptomatic, trained subjects. To define the number of repeated measurements that provide acceptable level of reliability. To investigate variability of the measurements over time of 5 days and the reliability of duplicate analysis of images. ⋯ Two repeated measurements for TrA thickness and at least three measurements for TrA thickness change are needed to achieve acceptable levels of intra- and inter-rater reliability. In healthy trained volunteers TrA thickness and thickness change are relatively stable parameters over a 5-day period. Duplicate analysis of the same images by two blinded observers is reliable.
-
To gain insight into a new technology, a novel facet arthroplasty device (TFAS) was compared to a rigid posterior fixation system (UCR). The axial and bending loads through the implants and at the bone-implant interfaces were evaluated using an ex vivo biomechanical study and matched finite element analysis. Kinematic behaviour has been reported for TFAS, but implant loads have not. Implant loads are important indicators of an implant's performance and safety. The rigid posterior fixation system is used for comparison due to the extensive information available about these systems. ⋯ These results are most applicable to the immediate post-operative period prior to remodelling of the bone-implant interface since the UCR and TFAS implants are intended for different service lives (UCR--until fusion, TFAS--indefinitely). TFAS reproduced intact-like anterior column load-sharing--as measured by disc pressure. The highest bone-implant moment of 3.1 Nm was measured in TFAS and for the same loading condition the UCR interface moment was considerably lower (0.4 Nm). For other loading conditions, the differences between TFAS and UCR were smaller, with the UCR sometimes having larger values and for others the TFAS was larger. The long-term physiological meaning of these findings is unknown and demonstrates the need for a better understanding of the relationship between spinal arthroplasty devices and the host tissue as development of next generation motion-preserving posterior devices that hope to more accurately replicate the natural functions of the native tissue continues.
-
This study aimed to establish radiographic standard values for cervical spine morphometry, alignment, and range of motion (ROM) in both male and female in each decade of life between the 3rd and 8th and to elucidate these age-related changes. ⋯ The standard values and age-related changes in cervical anatomy, alignment, and ROM for males and females in each decade between the 3rd and 8th were established. Cervical lordosis in the neutral position develops with aging, while extension ROM decreases gradually. These data will be useful as normal values for the sake of comparison in clinical practice.
-
Comparative Study
The evolutionary importance of cell ratio between notochordal and nucleus pulposus cells: an experimental 3-D co-culture study.
Notochordal cells and nucleus pulposus cells are co-existing in the intervertebral disc at various ratios among different mammalians. This fact rises the question about the interactions and the evolutionary relevance of this phenomenon. It has been described that these relatively large notochordal cells are mainly dominant in early lifetime of all vertebrates and then differences occur with ageing. Human, cattle, sheep, and goat lose the cells with age, whereas rodents and lagomorphs maintain these throughout their lifetime. ⋯ The stimulating effect of NC was confirmed and the ideal ratio of NPC: NC was found to be ~50:50. This has direct implications for tissue-engineering approaches, which aim to repopulate discs with NP-like precursor cells.
-
To evaluate the effectiveness of posterior occipitocervical reconstruction using the anchors of cervical pedicle screws and plate-rod systems for patients with congenital osseous anomalies at the craniocervical junction. ⋯ The results of the present study indicate that posterior occipitocervical reconstruction using the anchors of cervical pedicle screws and plate-rod systems is an effective technique for treatment of deformities and/or instability caused by congenital osseous anomalies at the craniocervical junction.