European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Single position lateral fusion with robotic assistance eliminates the need for surgical staging while harnessing the precision of robotic adjuncts. We expand on this technique by demonstrating the technical feasibility of placing bilateral pedicle screws with S2-alar-iliac (S2AI) fixation while in the lateral position. ⋯ We demonstrate here the technical feasibility of single position robot-assisted placement of S2-alar-iliac screws in the lateral decubitus position for single position surgery.
-
Robotic-assisted spine surgery is an emerging field that is growing in utilization. Intraoperative robotic surgical units cost upwards of $600,000 for medical facilities to purchase. Despite significant cost barriers, these devices are highly marketable for hospitals and physicians. ⋯ Robotic-assisted lumbar fusion is on the rise. Patients who had private insurance, were diagnosed with spondylolisthesis, and who had lumbar fusion via the anterior approach were more likely to undergo lumbar fusion using robotic assistance.
-
Review Meta Analysis
Comparison of clinical outcomes associated with spinal cord stimulation (SCS) or conventional medical management (CMM) for chronic pain: a systematic review and meta-analysis.
This study aims to evaluate the efficacy and safety of spinal cord stimulation (SCS) compared to conventional medical management (CMM) for patients diagnosed with chronic pain. Furthermore, the study seeks to compare the utilization of analgesics, as well as the long-term outcomes in terms of quality of life and functional capacity. ⋯ SCS is an effective treatment to relieve the pain level of chronic pain, decrease analgesic usage, and increase long-term quality of life and functional capacity.
-
To manufacture and test 3D printed novel design titanium spine rods with lower flexural modulus and stiffness compared to standard solid titanium rods for use in metastatic spine tumour surgery (MSTS) and osteoporosis. ⋯ By utilising novel design approach, we successfully generated a spine rod design portfolio with lower flexural modulus/stiffness profile and better CT/MR imaging compatibility for potential use in MSTS/other conditions such as osteoporosis. Thus, exploration of new rod designs in surgical application could enhance treatment outcome and improve quality of life for patients.
-
Multiple studies have analyzed the outcome after thoracic Vertebral Body Tethering (VBT). The results seem reproducible with most studies reporting coronal correction rates around 50% and a tether breakage rate near 20% at two years follow-up. There is a paucity of data on lumbar VBT, and no study has yet analyzed the radiographic outcome after lumbar VBT in a double tether technique at two years follow-up, which was the aim of this study. ⋯ VBT in the lumbar spine resulted in 50% coronal curve correction two years post-operatively despite a tether breakage in 90% of patients.