Sparing dysphagia/aspiration related structures using novel hybrid volumetric modulated arc therapy.
Studies using split field IMRT to spare dysphagia/aspiration related structures (DARS) have raised concern regarding dose uncertainty at matchline. This study explores the utility of hybrid VMAT in sparing the DARS and assesses matchline dose uncertainty in postoperative oral cavity cancer patients and compares it with VMAT. ⋯ h-VMAT achieves better sparing of DARS with no matchline dose uncertainty. Since these patients have swallowing dysfunction post-operatively, attempts should be made to spare these critical structures as much as possible.
-
To demonstrate the accuracy of an unsupervised (fully automated) software for fat segmentation in magnetic resonance imaging. The proposed software is a freeware solution developed in ImageJ that enables the quantification of metabolically different adipose tissues in large cohort studies. ⋯ The developed software is capable of segmenting the metabolically different adipose tissues with a high degree of accuracy. This free add-on software for ImageJ can easily have a widespread and enable large-scale population studies regarding the adipose tissue and its related diseases.
-
The quantitative assessment of Positron Emission Tomography (PET) scans using standardized uptake value and derived parameters proved to be superior to traditional qualitative assessment in several retrospective or mono-centric prospective reports. Since different scanners give different quantitative readings, a program for clinical trial qualification (CTQ) is mandatory to guarantee a reliable and reproducible use of quantitative PET in prospective multi-centre clinical trials and in every-day clinical life. ⋯ The (68)Ge phantom proved a reliable tool for PET scanner qualification, able to significantly reduce the potential sources of error while increasing the reproducibility of PET derived quantitative parameter measurement.
-
Demonstrate an objective procedure to quantify image quality in digital subtraction angiography (DSA) and suggest thresholds for acceptability and constancy tests. ⋯ Objective evaluation of DSA images using CNR is feasible with dedicated phantom measurements. An objective methodology has been suggested for acceptance tests compliant with the IEC/DIN standards. The defined overall scores can serve to fix a reproducible baseline for constancy tests, as well as to study the device stability within one acquisition series and compare different imaging protocols. This work provides aspects that have not been included in the recent European guidelines on Criteria for Acceptability of Medical Radiological Equipment.
-
The aim of this paper was to determine experimentally the entrance surface air kerma (ESAK) and kerma-area product (KAP) levels to patients and scatter doses at the cardiologist's eyes during paediatric interventional cardiology (IC) procedures for Chile, on the basis of measurements taken from X-ray systems characterization for different thicknesses of polymethyl methacrylate, together with the average values of fluoroscopy time and number of cine frames for ten paediatric IC procedures. The range of cumulative ESAK values when the different clinical procedures were simulated was from 2 to 1100 mGy. ⋯ Large differences between the X-ray systems were found in our study. Standardized guidelines in terms of X-ray system setting and protocols should be developed for hospitals that perform paediatric IC procedures in Chile.