Medicina
-
Background and Objectives: Multidrug-resistant microorganisms have made treating bacterial infections challenging. Resistance to antibiotics is expected to overcome efforts to produce new, effective antibacterial medication that is lifesaving in many situations. Infective endocarditis (IE) is a life-threatening infection that affects 5-15 per 100,000 patients annually and requires rapid antibiotic therapy to prevent morbidity and mortality. ⋯ Although the Gram-negative infections were more severe, their resistance patterns were similar to Gram-positive bacteria. As resistance patterns increase, more efforts should be made to prevent a healthcare catastrophe. At the same time, careful prophylaxis should be considered in patients at risk, including those with central catheters, undergoing dental procedures, and with poor oral hygiene.
-
Background and Objectives: Chronic painful midportion Achilles combined with plantaris tendinopathy can be a troublesome condition to treat. The objective was to prospectively follow patients subjected to ultrasound (US)- and color doppler (CD)-guided wide awake, local anesthetic, no-tourniquet (WALANT) surgery in a private setting. Material and Methods: Twenty-six Swedish patients (17 men and 9 women, mean age 50 years (range 29-62)) and eight international male patients (mean age of 38 years (range 25-71)) with combined midportion Achilles and plantaris tendinopathy in 45 tendons altogether were included. ⋯ For the Swedish patients, the mean VISA-A score increased from 34 (0-64) before surgery to 93 (61-100) after surgery (p < 0.001). There were two complications, one wound rupture and one superficial skin infection. Conclusions: For patients suffering from painful midportion Achilles tendinopathy and plantaris tendinopathy, US + CD-guided surgical Achilles tendon scraping and plantaris tendon removal showed a high satisfaction rate and good functional results 1 year after surgery.
-
Background and Objectives: There are reports of false qualitative HBsAg results, because of various causes, such as samples with low HBsAg concentrations that may produce false positives. The main aims of this study were to validate the analytical accuracy and to assess the utility of the Elecsys assay compared to that of the qualitative HbsAg assay as a screening test in resolving equivocal qualitative HbsAg results. Materials and Methods: The limit of blank (LoB), the limit of detection (LoD), the limit of quantification (LoQ), and linearity were estimated to validate the analytical accuracy of the Elecsys HBsAg II Quant assay. ⋯ The Kappa agreement between the two assays was almost perfect, at 0.9669, despite seven discordant results. With a specificity of 100% at new cut-off index value ≥5.42, about 78 samples (17%, 78/449) with index value ≥5.42 were interpreted as positives without further duplicate tests, however the remaining 371 samples with index value <5.42 need to be confirmed with additional HBV marker assays. Conclusions: We confirm that the Elecsys HBsAg II Quant assay is accurate and sensitive for HBV infection and recommend it as an alternative confirmatory HBsAg assay for resolving equivocal qualitative HBsAg results.
-
Background and Objectives: Cardiopulmonary bypass (CPB) is an extracorporeal circuit that provides surgical access to an immobile and bloodless area, allowing for technical and procedural advances in cardiothoracic surgery. CBP can alter the integrity of the blood-brain barrier and cause changes in intracranial pressure (ICP) postoperatively. Optical nerve sheath diameter (ONSD) measurement is among the alternative non-invasive methods for ICP monitoring. ⋯ Calculated nICPONSD values of 11.0 mm Hg (1.0-21.0) for the right eye and 10.89 mm Hg (1.0-21.0) for the left eye were found. It was observed that there was a significant increase in the ONSD and nlCPONSD values recorded during the extracorporeal circulation of all patients compared to the baseline values (p < 0.005). Conclusions: During extracorporeal circulation, ultrasound-guided ONSD measurement is an easy, inexpensive and low-complication method that can be performed at the bedside during the operation to monitor ICP changes.
-
Randomized Controlled Trial
In Vitro Testing and Clinical Handling of a Novel Implant Positioning Technology for Proximal Humeral Plating.
Fractures of the proximal humerus are common, particularly in elderly populations. Anatomical locking plates target stabilization with a multitude of screws spanning into the humeral head. Sound implant placement and screw length determination are key for a successful clinical outcome but are difficult to obtain from planar X-rays. A novel implant positioning technology for proximal humerus plating (Xin1) outputs screw lengths suggestions and plate position based on hole projections in conventional X-ray images. This study investigated the performance of a prototype Xin1 system in a postmortem (in vitro) experiment as well as in a clinical handling test. ⋯ Results suggest a strong potential of the Xin1 assistance technology to enhance the surgical procedure and patient outcomes in the rising incidence of osteoporotic humeral fractures. Robust performance in a real-life fracture situation was observed. In-depth validation of the system is, however, needed before placing it into clinical practice.