Foot & ankle international
-
Temporary Kirschner wire fixation (K-wire) is a widely used, low-cost fixation method for the correction of hammertoe deformity. Reported complications associated with K-wires prompted the development of new implants over the past decade. However, there is a lack of literature on comparative studies analyzing functional outcomes using validated questionnaires. The purpose of this study was to analyze functional outcomes in patients who had undergone proximal interphalangeal joint fusion using 2 types of intramedullary implant, the Smart Toe and the TenFuse, and to compare them with the outcomes in patients treated with standard K-wire fixation. ⋯ Level III, comparative series.
-
External rotation, lateral, and sagittal stress tests are commonly used to diagnose syndesmotic injuries, but their efficacy remains unclear. The purpose of this study was to characterize applied stresses with fibular motion throughout the syndesmotic injury spectrum. We hypothesized that sagittal fibular motion would have greater fidelity in detecting changes in syndesmotic status compared to mortise imaging. ⋯ Syndesmotic injuries may be better diagnosed using stress tests that are assessed using lateral imaging than standard mortise view imaging.