European journal of emergency medicine : official journal of the European Society for Emergency Medicine
-
Use of automated systems to aid identification of patient deterioration in routine hospital practice is limited and their impact on patient outcomes remains unclear. This study was designed to evaluate the feasibility of implementing an electronic observation chart with automated early warning score (EWS) calculation in the high-acuity area of an emergency department. ⋯ In this study, the feasibility and limitations of implementing an electronic observation chart in the ED were demonstrated. Accurate EWS documentation was more frequent after implementation of the electronic observation chart. Retrospective analysis suggests that the use of an electronic observation system may lead to a greater percentage of observations being taken from those patients with a higher EWS.