Biochemia medica : časopis Hrvatskoga društva medicinskih biokemičara
-
In a contemporary clinical laboratory it is very common to have to assess the agreement between two quantitative methods of measurement. The correct statistical approach to assess this degree of agreement is not obvious. ⋯ Data can be analyzed both as unit differences plot and as percentage differences plot. The B&A plot method only defines the intervals of agreements, it does not say whether those limits are acceptable or not. Acceptable limits must be defined a priori, based on clinical necessity, biological considerations or other goals. The aim of this article is to provide guidance on the use and interpretation of Bland Altman analysis in method comparison studies.
-
Biochem Med (Zagreb) · Jan 2015
Comparative Study Controlled Clinical TrialA comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry.
Total 25-hydroxyvitamin D [25(OH)D] is the most reliable indicator of vitamin D status. In this study, we compared two automated immunoassay methods, the Abbott Architect 25-OH Vitamin D assay and the Roche Cobas Vitamin D total assay, with the liquid chromatography-tandem mass spectrometry (LC-MS/MS). ⋯ Both immunoassays demonstrated acceptable performance, but the Roche Cobas assay demonstrated better performance than the Abbott Architect in the studied samples.
-
Recent findings of authorship criteria violations in the manuscripts submitted to Biochemia Medica show that almost 40% of authors do not meet necessary criteria for authorship and thus indicate the need for better dissemination of editorial policy on authorship in our journal. We believe that such cases are mostly due to the authors' unawareness or the lack of understanding of the authorship criteria. With this article we therefore wish to declare our editorial policy on authorship and authorship criteria. ⋯ All authors should be responsible for content of the article and have to know other authors' contributions to the study. Biochemia Medica will follow recommendations provided by Committee on Publication Ethics (COPE) flowcharts for possible disputes. By adhering to this procedure we hope to raise awareness about the importance of compliance with ICMJE authorship recommendations.
-
Biochem Med (Zagreb) · Jan 2015
Clinical TrialDetection of acute kidney injury in premature asphyxiated neonates by serum neutrophil gelatinase-associated lipocalin (sNGAL)--sensitivity and specificity of a potential new biomarker.
Acute kidney injury (AKI) is common in neonatal intensive care units (NICU). In recent years, every effort is made for early detection of AKI. Our hypothesis was that serum neutrophil gelatinase-associated lipocalin (sNGAL) may be a reliable screening test for early diagnosis of AKI in premature neonates after perinatal asphyxia. Therefore, our aim was to assess the diagnostic accuracy of sNGAL for AKI in premature asphyxiated neonates. ⋯ In premature asphyxiated neonates sNGAL measured within the first 4 hours of DOL 1 is predictive of the occurrence and severity of AKI. Therefore, plasma levels of NGAL may be used for early diagnosis of AKI in these patients.
-
Biochem Med (Zagreb) · Jan 2015
The use of S-Monovette is effective to reduce the burden of hemolysis in a large urban emergency department.
Due to the high prevalence of hemolysis in specimens received from the emergency department (ED), several strategies have been proposed to improve sample quality, but none of these seem effective to overcome the problem. In a preliminary study we showed that the use of S-Monovette blood collection system was effective to lower the risk of hemolysis in venous blood samples collected from intravenous catheters. This study was hence aimed to verify whether the replacement of a conventional vacuum system with S-Monovette may be effective to reduce the burden of hemolysis in the daily practice of a large urban ED. ⋯ Results of our study confirm that the introduction of the Sarstedt S-Monovette blood tubes has reduced the hemolysis rate in the emergency department compared to the previously used BD Vacutainer® SST II Plus plastic serum tubes.