British journal of anaesthesia
-
Comparative Study Clinical Trial Controlled Clinical Trial
Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patients.
We have analysed the clinical agreement between two methods of continuous cardiac output measurement pulse contour analysis (PCCO) and a continuous thermodilution technique (CCO), were both compared with the intermittent bolus thermodilution technique (BCO). Measurements were performed in 26 cardiac surgical patients (groups 1 and 2, 13 patients each, with an ejection fraction > 45% and < 45%, respectively) at 12 selected times. During operation, mean differences (bias) between PCCO-BCO and CCO-BCO did not differ in either group. ⋯ Significantly higher absolute bias values of PCCO-BCO compared with CCO-BCO were also found early after operation in the ICU. Thus PCCO and CCO provided comparable measurements during coronary bypass surgery. After marked changes in SVR, further calibration of the PCCO device is necessary.
-
Randomized Controlled Trial Multicenter Study Comparative Study Clinical Trial
Comparison of intubating conditions after rapacuronium (Org 9487) and succinylcholine following rapid sequence induction in adult patients.
We have assessed intubating conditions provided by rapacuronium (Org 9487) and succinylcholine after rapid sequence induction of anaesthesia in adult patients undergoing elective surgery. We studied 335 patients, ASA I and II, in five centres. Two hundred and thirty-four subjects with normal body weight and 101 obese subjects were allocated randomly to one of four treatment groups differing in the neuromuscular blocking drug administered (rapacuronium 1.5 mg kg-1 or succinylcholine 1 mg kg-1) and in the technique used for induction of anaesthesia (fentanyl 2-3 micrograms kg-1 with thiopental 3-6 mg kg-1 or alfentanil 20 micrograms kg-1 with propofol 1.5-2 mg kg-1). ⋯ After intubation, the maximum increase in heart rate averaged 23.1 (SD 25.4%) and 9.4 (26.1%) after rapacuronium and succinylcholine, respectively (P < 0.001). Pulmonary side effects (bronchospasm and increased airway pressure) were observed in 10.7% (95% CI 5.8-17%) and 4.1% (95% CI 1.3-8.8%) of patients given rapacuronium and succinylcholine, respectively (P = 0.021). We conclude that after rapid sequence induction of anaesthesia in adults, clinically acceptable intubating conditions were achieved less frequently after rapacuronium 1.5 mg kg-1 than after succinylcholine.
-
Randomized Controlled Trial Multicenter Study Comparative Study Clinical Trial
Transient neurological symptoms after spinal anaesthesia with hyperbaric 5% lidocaine or general anaesthesia.
Transient neurotoxicity of concentrated local anaesthetics has been thought to be the main reason for transient neurological symptoms after spinal anaesthesia. Profound musculoligamental relaxation by high doses of local anaesthetics may contribute to the development of postoperative musculoskeletal pain. ⋯ Transient neurological symptoms, consisting of pain in the buttocks or pain radiating symmetrically to the lower extremities, occurred in eight patients (27%) receiving spinal anaesthesia and in one patient (3%) receiving general anaesthesia (P < 0.05). We conclude that a transient neurotoxic effect of hyperbaric lidocaine 50 mg ml-1 is probably the main reason for transient neurological symptoms after spinal anaesthesia but musculoligamental relaxation may contribute to the development of low back or leg pain after both anaesthetic techniques.
-
Randomized Controlled Trial Clinical Trial
Sevoflurane requirements for tracheal intubation with and without fentanyl.
We studied 80 healthy ASA 1 patients (aged 20-52 yr) to determine if fentanyl affects sevoflurane requirements for achieving 50% probability of no movement in response to laryngoscopy and tracheal intubation (MAC-TI). Patients were allocated randomly to one of four fentanyl dose groups (0, 1, 2 and 4 micrograms kg-1). Patients in each group received sevoflurane at a pre-selected end-tidal concentration according to an 'up-down' technique. ⋯ The MAC-TI of sevoflurane was 3.55% (95% confidence intervals 3.32-3.78%), and this was reduced markedly to 2.07%, 1.45% and 1.37% by addition of fentanyl 1, 2 and 4 micrograms kg-1, with no significant difference in the reduction between 2 and 4 micrograms kg-1, showing a ceiling effect. Fentanyl attenuated haemodynamic responses (HR and MAP) to tracheal intubation in a dose-dependent manner, even with decreasing concomitant sevoflurane concentration. Fentanyl 4 micrograms kg-1 suppressed the changes in HR and MAP more effectively than fentanyl 1 or 2 micrograms kg-1 at sevoflurane concentrations close to MAC-TI.
-
Comparative Study Clinical Trial Controlled Clinical Trial
Oral mucosal blood flow, plasma epinephrine and haemodynamic responses after injection of lidocaine with epinephrine during midazolam sedation and isoflurane anaesthesia.
We have investigated the relationship between oral mucosal blood flow and plasma epinephrine concentration, and the effects of conscious sedation vs general anaesthesia on haemodynamic responses after submucosal epinephrine injection in 14 subjects. The same seven patients were studied both as controls and after sedation. For sedation, midazolam i.v. was used. ⋯ There were no differences in haemodynamic changes except for heart rate, between the three groups. These results suggest that plasma epinephrine concentration after submucosal injection depends on the initial mucosal blood flow in the injected area. Haemodynamic changes, except heart rate, in the sedation and general anaesthesia groups were similar despite different changes in maximum plasma epinephrine concentration.