Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery.
Assessment of cardiac output (CO) by the FloTrac/Vigileo system may offer a less invasive means of determining the CO than either the pulmonary artery catheter (PAC) or the PiCCOplus system. The aim of this study was to compare CO measurements made using the FloTrac/Vigileo system with upgraded software (FCO, Edwards Lifesciences, Irvine CA, USA), the PiCCOplus system (PCO, Pulsion Medical Systems, Munich, Germany) and continuous CO monitoring using a PAC (CCO; Vigilance monitoring, Edwards Lifesciences, Irvine CA, USA) with intermittent pulmonary artery thermodilution (ICO). The study was conducted in patients undergoing elective cardiac surgery. ⋯ The performance of the FloTrac/Vigileo system, the PiCCOplus, and the Vigilance CCO monitoring for CO measurement were comparable when tested against intermittent thermodilution in patients undergoing elective cardiac surgery.
-
Randomized Controlled Trial Comparative Study
Faster wash-out and recovery for desflurane vs sevoflurane in morbidly obese patients when no premedication is used.
The aim of this study was to compare desflurane vs sevoflurane kinetics and dynamics in morbidly obese patients and their recovery profile when no premedication had been used. ⋯ Desflurane provides faster wash-in and wash-out than sevoflurane in morbidly obese patients, and recovery is much faster after desflurane administration when no premedication has been used.
-
Randomized Controlled Trial
Effects of using two airway exchange catheters on laryngeal passage during change from a double-lumen tracheal tube to a single-lumen tracheal tube.
A thin airway exchange catheter (AEC) is often used for changing from a double-lumen tracheal tube (DLT) to a single-lumen tracheal tube. However, passage of the tube into the trachea is often difficult. The purpose of this study was to evaluate the effectiveness of using two AECs for tracheal tube exchange. ⋯ The use of two AECs reduces the incidence of impingement of the tube into the trachea during tracheal tube exchange.
-
Comparative Study
Post-tetanic count at adductor pollicis is a better indicator of early diaphragmatic recovery than train-of-four count at corrugator supercilii.
Because the intensity of neuromuscular block at the diaphragm (DIA) is indirectly assessed, the electromyographic measurements of the DIA (DIA(EMG)) from surface electrodes were related to information provided by visual estimation of neuromuscular transmission at the adductor pollicis (AP) and the corrugator supercilii (CSC) during recovery from vecuronium block. ⋯ PTC(AP) may better reflect early recovery of vecuronium-induced DIA paralysis than TOF(CSC). The findings suggested that PTC(AP)