British journal of anaesthesia
-
Observational Study
Introduction of an electronic physiological early warning system: effects on mortality and length of stay.
The Worthing physiological scoring system (PSS) was first validated in 2005 as a tool to predict hospital mortality on admission and was subsequently introduced into clinical practice at Worthing Hospital, UK. Five years on, this study was conducted to determine the effects on mortality and length of stay (LOS) after the introduction of electronic alerting software using the PSS. In addition, we investigated whether the Worthing PSS predictive ability could be improved by addition of further variables. ⋯ The introduction of an electronic alerting PSS did not lead to a reduction in mortality when adjusted for severity of illness defined by physiological variables. Predictive performance was not enhanced by the addition of biochemical variables and co-morbidities.
-
Multicenter Study
Preoperative estimated glomerular filtration rate and the risk of major adverse cardiovascular and cerebrovascular events in non-cardiac surgery‡
Chronic kidney disease is an independent predictor of perioperative cardiovascular morbidity and mortality. We analysed the preoperative estimated glomerular filtration rate (eGFR) as a risk factor for perioperative major adverse cardiovascular and cerebrovascular events (MACCE) in non-cardiac surgery. ⋯ Perioperative MACCE increase with declining eGFR, primarily when <45 ml min(-1) 1.73 m(-2). We recommend the use of preoperative eGFR for cardiovascular risk assessment.
-
Comparative Study Observational Study
Accuracy of impedance cardiography for evaluating trends in cardiac output: a comparison with oesophageal Doppler.
Impedance cardiography (ICG) enables continuous, beat-by-beat, non-invasive, operator-independent, and inexpensive cardiac output (CO) monitoring. We compared CO values and variations obtained by ICG (Niccomo™, Medis) and oesophageal Doppler monitoring (ODM) (CardioQ™, Deltex Medical) in surgical patients. ⋯ ICG appears to be a reliable method for the non-invasive monitoring of CO in patients undergoing general surgery.
-
Accidental awareness during general anaesthesia (AAGA) with recall is a potentially distressing complication of general anaesthesia that can lead to psychological harm. The 5th National Audit Project (NAP5) was designed to investigate the reported incidence, predisposing factors, causality, and impact of accidental awareness. ⋯ The NAP5 methodology may be used to assess new reports of AAGA in a standardized manner, especially for the development of an ongoing database of case reporting. This paper is a shortened version describing the protocols, methods, and data analysis from NAP5--the full report can be found at http://www.nationalauditprojects.org.uk/NAP5_home.
-
We have recently described a bi-directional bulk flow of cerebrospinal fluid (CSF) (coined 'the CSF rebound mechanism') after the use of high-volume caudal block in infants, which may explain the secondary longitudinal spread of the block. If important the initial cephalad transfer of CSF should be of such a magnitude that it would cause a transient reduction in cerebral blood flow (CBF) and cerebral oxygenation. The primary aim of this observational study was to delineate the magnitude of the reduction of CBF velocity (CBFV) associated with high-volume caudal block in infants. ⋯ High-volume caudal block causes a biphasic change in CBFV and was also found to affect cerebral oxygenation. Our findings lend further support to 'the CSF rebound mechanism' for secondary spread of high-volume caudal block.