British journal of anaesthesia
-
Observational Study
Introduction of an electronic physiological early warning system: effects on mortality and length of stay.
The Worthing physiological scoring system (PSS) was first validated in 2005 as a tool to predict hospital mortality on admission and was subsequently introduced into clinical practice at Worthing Hospital, UK. Five years on, this study was conducted to determine the effects on mortality and length of stay (LOS) after the introduction of electronic alerting software using the PSS. In addition, we investigated whether the Worthing PSS predictive ability could be improved by addition of further variables. ⋯ The introduction of an electronic alerting PSS did not lead to a reduction in mortality when adjusted for severity of illness defined by physiological variables. Predictive performance was not enhanced by the addition of biochemical variables and co-morbidities.
-
Multicenter Study
Preoperative estimated glomerular filtration rate and the risk of major adverse cardiovascular and cerebrovascular events in non-cardiac surgery‡
Chronic kidney disease is an independent predictor of perioperative cardiovascular morbidity and mortality. We analysed the preoperative estimated glomerular filtration rate (eGFR) as a risk factor for perioperative major adverse cardiovascular and cerebrovascular events (MACCE) in non-cardiac surgery. ⋯ Perioperative MACCE increase with declining eGFR, primarily when <45 ml min(-1) 1.73 m(-2). We recommend the use of preoperative eGFR for cardiovascular risk assessment.
-
We aimed to create a theoretical tool to model the effect of three haemostatic agents containing fibrinogen (therapeutic plasma, cryoprecipitate, and fibrinogen concentrate) on the patient's plasma fibrinogen level. ⋯ We successfully developed two theoretical tools answering the questions: 'How much therapeutic plasma, cryoprecipitate, or fibrinogen concentrate would be needed to achieve a specified target fibrinogen level?' and 'What would be the resultant fibrinogen level for a specified amount of haemostatic agent?' The current tools are not intended for clinical application, but they are potentially useful for educational purposes.
-
Component reductions in oxygen delivery generate variable haemodynamic and stress hormone responses.
In clinical practice, global oxygen delivery (DO2) is often considered as a whole; however pathological and adaptive responses after a decrease in individual constituents of the DO2 equation (cardiac output, haemoglobin, oxyhaemoglobin saturation) are likely to be diverse. We hypothesized that an equivalent decrease in DO2 after reductions in each separate component of the equation would result in different haemodynamic, tissue oxygenation, and stress hormonal responses. ⋯ Decreasing global oxygen delivery, achieved by targeted reductions in its separate components, induces varying circulatory, tissue oxygen tension, and stress hormone responses. We conclude that not all oxygen delivery is the same; this disparity should be emphasized in classical teaching and re-evaluated in patient management.