Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2014
Clinical TrialAnalysis of plethysmographic waveform changes induced by beach chair positioning under general anesthesia.
During shoulder surgery, patients typically are placed in the beach chair position. In rare cases, this positioning has resulted in devastating outcomes of postoperative cerebral ischemia (Cullen and Kirby in APSF Newsl 22(2):25-27, 2007; Munis in APSF Newsl 22(4):82-83, 2008). This study presents a method to noninvasively and continuously hemodynamically monitor patients during beach chair positioning by using the photoplethysmograph signal recorded from a commercial pulse oximeter. ⋯ The PPG was more accurate at monitoring the change to beach chair position than blood pressure or heart rate. With vasoactive drugs, pulse-associated PPG oscillations decreased only with phenylephrine while respiration-associated oscillations did not change. Frequency domain analysis of the PPG signal may be a better tool than traditional noninvasive hemodynamic parameters at monitoring patients during beach chair position surgery.
-
J Clin Monit Comput · Dec 2014
Lessons learned from closed loops in engineering: towards a multivariable approach regulating depth of anaesthesia.
In this paper is presented a brief state of art regarding the multivariable formulation for controlling the depth of anaesthesia by means of two intravenously administrated drugs, i.e. propofol and remifentanil. In a feasibility study of determining a suitable variable to quantify analgesia levels in patients undergoing cardiac surgery, the bispectral index and an electromyogram-based surrogate variable are proposed as the controlled variables. The study is carried on in the context of implementing a multivariable predictive control algorithm. The simulation results show that such a paradigm is feasible, although it does not guarantee perfect knowledge of the analgesia level-in other words, the variable is not validated against typical evaluations of the pain levels (e.g. clinical scores).
-
J Clin Monit Comput · Dec 2014
Individualizing propofol dosage: a multivariate linear model approach.
In the last decades propofol became established as an intravenous agent for the induction and maintenance of both sedation and general anesthesia procedures. In order to achieve the desired clinical effects appropriate infusion rate strategies must be designed. Moreover, it is important to avoid or minimize associated side effects namely adverse cardiorespiratory effects and delayed recovery. ⋯ The results obtained in the test set comprising a broad range of characteristics are satisfactory since the models are able to predict bolus, infusion rates and the effect-site concentrations comparable to those of TCI. Furthermore, comparisons of the effect-site concentrations for dosages predicted by the proposed Linear model and the Marsh model for the same target concentration is achieved using Schnider model and a factorial design on the factors (patients characteristics). The results indicate that the Linear model predicts a dosage profile that is faster in leading to an effect-site concentration closer to the desired target concentration.
-
J Clin Monit Comput · Dec 2014
Measuring gas exchange with step changes in inspired oxygen: an analysis of the assumption of oxygen steady state in patients suffering from COPD.
Bedside estimation of pulmonary gas exchange efficiency may be possible from step changes in FIO2 and subsequent measurement of arterial oxygenation at steady state conditions. However, a steady state may not be achieved quickly after a change in FIO2, especially in patients with lung disease such as COPD, rendering this approach cumbersome. This paper investigates whether breath by breath measurement of respiratory gas and arterial oxygen levels as FIO2 is changed can be used as a much more rapid alternative to collecting data from steady state conditions for measuring pulmonary gas exchange efficiency. ⋯ Calculated model parameters were shown to be similar for the two data sets, with Bland-Altman bias and limits of agreement of -0.4 and -3.0 to 2.2 % for calculation of pulmonary shunt and 0.17 and -0.47 to 0.81 kPa for alveolar to end-capillary PO2, a measure of oxygen abnormality due to shunting plus regions of low [Formula: see text] A/[Formula: see text] ratio. This study shows that steady state oxygen levels may not be necessary when estimating pulmonary gas exchange using changes in FIO2. As such this technique may be applicable in patients with lung disease such as COPD.
-
J Clin Monit Comput · Dec 2014
Melodic algorithms for pulse oximetry to allow audible discrimination of abnormal systolic blood pressures.
An anesthesiologist must remain vigilant of the patient's clinical status, incorporating many independent physiological measurements. Oxygen saturation and heart rate are represented by continuous audible tones generated by the pulse oximeter, a mandated monitoring device. Other important clinical parameters--notably blood pressure--lack any audible representation beyond arbitrarily-configured threshold alarms. ⋯ A rhythmic variation in which additional auditory information was conveyed only at halftime intervals, with every other "beat" of the pulse oximeter, was strongly favored. The respondents also strongly favored the use of musical chords over single tones. Given three algorithms of tones embedded in the pulse oximeter signal, anesthesiologists preferred a melodic tone to signal a significant change in blood pressure.