Journal of clinical monitoring and computing
-
J Clin Monit Comput · Feb 2016
Evaluation of the Microstat™ sublingual PCO2 monitor in ambulatory patients.
Physicians often need to measure arterial PCO2 in clinical practice. Arterial blood gas sampling is typically available only in hospitals and may be unpleasant for patients. Minimally invasive techniques for measuring PCO2 offer the potential for overcoming these limitations. ⋯ The MicroStat sublingual PCO2 monitor over-estimates arterial PCO2 with wide limits of agreement. Test-retest repeatability was poor. Use of sublingual PCO2 monitoring with the MicroStat monitor cannot currently replace blood gas sampling.
-
J Clin Monit Comput · Feb 2016
A multi-channel acoustics monitor for perioperative respiratory monitoring: preliminary data.
This study pertains to a six-channel acoustic monitoring system for use in patient monitoring during or after surgery. The base hardware consists of a USB data acquisition system, a custom-built six-channel amplification system, and a series of microphones of various designs. The software is based on the MATLAB platform with data acquisition drivers installed. ⋯ We hypothesize that the above mentioned arrangement may be helpful to the anesthesiologist in recognizing clinical conditions like wheezing, bronchospasm, endobronchial intubation, and apnea. The study also evaluated various types of microphone designs used to transduce breath sounds. The system also features selectable band-pass filtering using MATLAB algorithms as well as a collection of recordings obtained with the system to establish what respiratory acoustic signals look like under various conditions.
-
Current hypoxic guards systems fail to maintain the inspired O2 concentration (FIO2) ≥ 21 % across the entire fresh gas flow (FGF) range when a second carrier gas is used (N2O or air). We examined the performance of the Maquet O2 Guard(®), a smart hypoxic guard that increases O2 delivery if an inspired hypoxic mixture is formed. After obtaining IRB approval and informed consent, 12 ASA I-II patients were enrolled. ⋯ FDO2 was increased to 60 % and FGF to 1 L min(-1) (the latter only if it was lower than 1 L min(-1) prior to activation of the O2 Guard). FIO2 increased to 25 % within 55 s after O2 Guard activation in all patients. The O2 Guard(®), an active inspired hypoxic guard, rapidly reverses and limits the duration of inspired hypoxic episodes when the delivered hypoxic guard fails to do so.
-
J Clin Monit Comput · Feb 2016
Randomized Controlled TrialImpact of early haemodynamic goal-directed therapy in patients undergoing emergency surgery: an open prospective, randomised trial.
Haemodynamic goal-directed therapies (GDT) may improve outcome following elective major surgery. So far, few data exist regarding haemodynamic optimization during emergency surgery. In this randomized, controlled trial, 50 surgical patients with hypovolemic or septic conditions were enrolled and we compared two algorithms of GDTs based either on conventional parameters and pressure pulse variation (control group) or on cardiac index, global end-diastolic volume index and stroke volume variation as derived from the PiCCO monitoring system (optimized group). ⋯ Likewise, SOFA scores were higher in the optimized group on POD1 (10.2 ± 2.5 versus 6.6 ± 2.2 in the control group, P = 0.001), POD2 (8.4 ± 2.6 vs 5.0 ± 2.4 in the control group, P = 0.002) and POD 3 (5.2 ± 3.6 and 2.2 ± 1.3 in the control group, P = 0.01). There was no significant difference in hospital mortality (13 % in the control group and 25 % in the optimized group). Haemodynamic optimization based on volumetric and flow PiCCO-derived parameters was associated with a less favorable postoperative outcome compared with a conventional GDT protocol during emergency surgery.