Journal of clinical monitoring and computing
-
J Clin Monit Comput · Oct 2018
Incidence of peripheral nerve injury during shoulder arthroplasty when motor evoked potentials are monitored.
To report the incidence of clinically detectable nerve injuries when utilizing transcranial electrical motor evoked potentials (MEPs) during shoulder arthroplasty. A retrospective review of patients undergoing shoulder arthroplasty with continuous IONM was performed. The criteria for nerve alerts was an 80% amplitude reduction in MEPs. ⋯ There were no false negatives, making sensitivity 100% and specificity was 93.9%. In the subset of cases in which an all-or-none criterion was retrospectively applied to just the deltoid, MEP alerts occurred in just 17.9% of cases; specificity improved to 98.0%. We conclude that utilization of the real-time diagnostic MEP data during shoulder arthroplasty aids surgeons in decision making regarding impending peripheral nerve injuries.
-
J Clin Monit Comput · Oct 2018
Observational StudyPredictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum.
Animal studies suggest that dynamic predictors remain useful in patients with pneumoperitoneum, but human data is conflicting. Our aim was to determine predictive values of pulse pressure variation (PPV) and stroke volume variation (SVV) in patients with pneumoperitoneum using LiDCORapid™ haemodynamic monitor. Standardised fluid challenges of colloid were administered to patients undergoing laparoscopic procedures, one fluid challenge per patient. ⋯ The gray zone of PPV ranged between 6.5 and 20.5% and that of SVV between 7.5 and 13%. During pneumoperitoneum, as measured by LiDCORapid™, PPV and SVV can predict fluid responsiveness, however their sensitivity is lower than the one reported in conditions without pneumoperitoneum. Trial registry number: (with the Australian New Zealand Clinical Trials Registry): ACTRN12612000456853.
-
J Clin Monit Comput · Oct 2018
Evaluation of the use of the fourth version FloTrac system in cardiac output measurement before and after cardiopulmonary bypass.
The FloTrac system is a system for cardiac output (CO) measurement that is less invasive than the pulmonary artery catheter (PAC). The purposes of this study were to (1) compare the level of agreement and trending abilities of CO values measured using the fourth version of the FloTrac system (CCO-FloTrac) and PAC-originated continuous thermodilution (CCO-PAC) and (2) analyze the inadequate CO-discriminating ability of the FloTrac system before and after cardiopulmonary bypass (CPB). Fifty patients were included. ⋯ The area under the receiver operating characteristic curve for CCO-FloTrac was 0.56, 0.52, 0.52, and 0.72 for all, ≥ ± 5, ≥ ± 10, and ≥ ± 15% CO changes (ΔCO) of CCO-PAC before CPB, respectively, and 0.59, 0.55, 0.49, and 0.46 for all, ≥ ± 5, ≥ ± 10, and ≥ ± 15% ΔCO of CCO-PAC after CPB, respectively. When CO < 4 L/min was considered inadequate, the Cohen κ coefficient was 0.355 and 0.373 before and after CPB, respectively. The accuracy, trending ability, and inadequate CO-discriminating ability of the fourth version of the FloTrac system in CO monitoring are not statistically acceptable in cardiac surgery.
-
J Clin Monit Comput · Oct 2018
Comparative StudyThe pressure exerted on the tongue during intubation with simultaneous cervical spine immobilisation: a comparison between four videolaryngoscopes and the Macintosh laryngoscope-a manikin study.
Excessive pressures exerted on the tongue during intubation may be associated with serious complications and may make intubation more difficult. The aim of this study was to evaluate five different intubating devices in the hands of experienced anaesthetists during simulated conditions of reduced cervical spine mobility. Forty senior anaesthetists participated in the study (female = 18, male = 22). ⋯ Their use may be associated with less complications. Furthermore, male anaesthetists exerted higher pressures on the soft tissues although this was neither statistically nor clinically significant. There was higher failed intubation rate in the male anaesthetist group.
-
J Clin Monit Comput · Oct 2018
Comparative StudyIn vitro performance of prefilled CO2 absorbers with the Zeus®.
Low fresh gas flows (FGFs) decrease the use of anesthetic gases, but increase CO2 absorbent usage. CO2 absorbent usage remains poorly quantified. The goal of this study is to determine canister life of 8 commercially available CO2 absorbent prepacks with the Zeus®. ⋯ Canister life of prefilled CO2 absorber canisters differs between brands. The FCU0.5-FGF relationship is not linear across the entire FGF range. Canister life of prepacks of the same brand for the Zeus and Aisys differs, the exact etiology of which is probably multifactorial, and may include differences in the absolute amount of absorbent and different rebreathing characteristics of the machines.