Journal of clinical monitoring and computing
-
J Clin Monit Comput · Feb 2020
ReviewClinical use of volumetric capnography in mechanically ventilated patients.
Capnography is a first line monitoring system in mechanically ventilated patients. Volumetric capnography supports noninvasive and breath-by-breath information at the bedside using mainstream CO2 and flow sensors placed at the airways opening. ⋯ Volumetric capnography goes one step forward standard respiratory mechanics and provides a new dimension for monitoring of mechanical ventilation. The article discusses the role of volumetric capnography for the clinical monitoring of mechanical ventilation.
-
J Clin Monit Comput · Feb 2020
Measuring arterial oxygen saturation from an intraosseous photoplethysmographic signal derived from the sternum.
Photoplethysmography performed on the peripheral extremities or the earlobes cannot always provide sufficiently rapid and accurate calculation of arterial oxygen saturation. The purpose of this study was to evaluate a novel photoplethysmography prototype to be fixed over the sternum. Our hypotheses were that arterial oxygen saturation can be determined from an intraosseous photoplethysmography signal from the sternum and that such monitoring detects hypoxemia faster than pulse oximetry at standard sites. ⋯ The sternal probe detected hypoxemia 28.7 s faster than a finger probe (95% CI 20.0-37.4 s, p < 0.001) and 6.6 s faster than an ear probe (95% CI 5.3-8.7 s, p < 0.001). In an experimental setting, arterial oxygen saturation could be determined using the photoplethysmography signal obtained from sternal blood flow after calibration with CO-oximetry. This method detected hypoxemia significantly faster than pulse oximetry performed on the finger or the ear.
-
J Clin Monit Comput · Feb 2020
Review Case ReportsSomatosensory evoked potential loss due to intraoperative pulse lavage during spine surgery: case report and review of signal change management.
Intraoperative neurophysiologic monitoring (IONM) includes various neurophysiologic tests which assess the functional integrity of the central and peripheral nervous systems during surgical procedures which place these structures at risk for iatrogenic injury. The rational for using IONM is to provide timely feedback of changes in neural function to enable the reversal of such insult before the development of irreversible neural injury. ⋯ We present this case to stress the importance of having knowledgeable members of the team who are well acquainted with all aspects of monitoring in close proximity to the operating room, so as to minimize troubleshooting time. Furthermore, we suggest the use of warm (body temperature) saline during irrigation to the surgical site, especially when using pressurized irrigation systems.
-
J Clin Monit Comput · Feb 2020
Randomized Controlled TrialPretreatment with glucose-insulin-potassium improves ventricular performances after coronary artery bypass surgery: a randomized controlled trial.
Heart failure is the main cause of poor outcome following open heart surgery and experimental studies have demonstrated that glucose-insulin-potassium (GIK) infusion exerts cardioprotective effects by reducing myocardial ischemia-reperfusion injuries. This randomized controlled trial was designed to assess the effects of GIK on left ventricular function in moderate-to-high risk patients undergoing on-pump isolated coronary artery bypass surgery (CABGS), or combined with aortic valve replacement. The primary outcomes were the effects of GIK on two- and three-dimensional left ventricular ejection fraction (2D and 3D-LVEF), and on transmitral flow propagation velocity (Vp), that occurred between the pre- and post-CPB periods. ⋯ In GIK pretreated patients (N = 54), 2-D and 3D-LVEF and Vp increased slightly during surgery (mean difference [MD] + 3.5%, 95% confidence interval [95% CI] - 0.2 to 7.1%, MD + 4.0%, 95% CI 0.6-7.4%, and MD + 22.2%, 95% CI 16.0-28.4%, respectively). In contrast, in the Placebo group (N = 46), 2D-and 3D-LVEF, as well as Vp all decreased after CPB (MD - 7.5% [- 11.6 to - 3.4%], MD - 12.0% [- 15.2 to - 8.8%] and MD - 21.3% [- 25.7 to - 16.9%], respectively). In conclusion, the administration of GIK resulted in better preservation of systolic and diastolic ventricular function in the early period following weaning from CPB.
-
J Clin Monit Comput · Feb 2020
Comparative Study Observational StudyComparison of the use of AnaConDa® versus AnaConDa-S® during the post-operative period of cardiac surgery under standard conditions of practice.
Changes have been made to the AnaConDa device (Sedana Medical, Stockholm, Sweden), decreasing its size to reduce dead space and carbon dioxide (CO2) retention. However, this also involves a decrease in the surface area of the activated carbon filter. The CO2 elimination and sevoflurane (SEV) reflection of the old device (ACD-100) were thus compared with the new version (ACD-50) in patients sedated after coronary artery bypass graft surgery. ⋯ During postoperative sedation, the use of ACD-50 significantly reduced CO2 retention. SEV reflection was slightly reduced. However, patients remained sufficiently sedated without increasing SEV infusion.