Journal of clinical monitoring and computing
-
J Clin Monit Comput · Aug 2021
On some factors determining the pressure drop across tracheal tubes during high-frequency percussive ventilation: a flow-independent model.
To provide an in vitro estimation of the pressure drop across tracheal tubes (ΔPTT) in the face of given pulsatile frequencies and peak pressures (Pwork) delivered by a high-frequency percussive ventilator (HFPV) applied to a lung model. Tracheal tubes (TT) 6.5, 7.5 and 8.0 were connected to a test lung simulating the respiratory system resistive (R = 5, 20, 50 cmH2O/L/s) and elastic (C = 10, 20, and 50 mL/cmH2O) loads. The model was ventilated by HFPV with a pulse inspiratory peak pressure (work pressure Pwork) augmented in 5-cmH2O steps from 20 to 45 cmH2O, yielding 6 diverse airflows. ⋯ RMSE of the model on the testing dataset was 1.17 cmH2O, r2 was 0.79 and estimation error was lower than 1 cmH2O in 68% of cases. As a result, even without a flow value, the physician would be able to evaluate ΔPTT pressure. If the present results of our bench study could be clinically confirmed, the use of a nonconventional ventilatory strategy as HFPV, would be safer and easier.
-
J Clin Monit Comput · Aug 2021
Defining information needs in neonatal resuscitation with work domain analysis.
To gain a deeper understanding of the information requirements of clinicians conducting neonatal resuscitation in the first 10 min after birth. ⋯ We propose two potential approaches to improving the clinician's information environment: (1) developing new sensors for the information we lack, and (2) employing principles of ecological interface design to present currently available information to the clinician in a more effective way.
-
J Clin Monit Comput · Aug 2021
Ultrasound prediction for vocal cord dysfunction in patients scheduled for anterior cervical spine surgeries: a prospective cohort study.
Prediction of vocal cord dysfunction is essential after anterior cervical spine surgeries. This study aimed to detect the validity of transcutaneous laryngeal ultrasonography by both anterior and novel lateral approaches for prediction of vocal cord edema and paralysis after anterior cervical spine surgeries. A prospective cohort study conducted on 90 patients scheduled for anterior cervical spine surgeries underwent consecutive pre and postoperative vocal cord examination for edema and paralysis by both anterior and lateral approaches laryngeal ultrasonography. ⋯ Overall incidence of vocal cord paralysis was 16.6%. Risk of vocal cord paralysis was statistically significant more in female, multiple disc herniation, lower and mixed disc levels, Langenbeck retractor, cage and plate and duration of surgery ≥ 1.5 h. Transcutaneous Laryngeal ultrasound is a valid comfortable tool for prediction of vocal cord edema and paralysis after anterior cervical spine surgeries with superiority of the novel lateral over anterior approach.
-
J Clin Monit Comput · Aug 2021
Evaluation of the relationship between slow-waves of intracranial pressure, mean arterial pressure and brain tissue oxygen in TBI: a CENTER-TBI exploratory analysis.
Brain tissue oxygen (PbtO2) monitoring in traumatic brain injury (TBI) has demonstrated strong associations with global outcome. Additionally, PbtO2 signals have been used to derive indices thought to be associated with cerebrovascular reactivity in TBI. However, their true relationship to slow-wave vasogenic fluctuations associated with cerebral autoregulation remains unclear. ⋯ PbtO2 does not appear to reliably respond in time to slow-wave fluctuations in MAP, as demonstrated on various VARIMA models across all patients. These findings suggest that PbtO2 should not be utilized in the derivation of cerebrovascular reactivity metrics in TBI, as it does not appear to be responsive to changes in MAP in the slow-waves. These findings corroborate previous results regarding PbtO2 based cerebrovascular reactivity indices.
-
J Clin Monit Comput · Aug 2021
Evaluation of a new wireless technique for continuous electroencephalography monitoring in neurological intensive care patients.
A novel wireless eight-channel electroencephalography (EEG) headset specially developed for ICUs was tested in regard of comparability with standard 10/20 EEG systems. The continuous EEG (cEEG) derivations via CerebAir EEG headset (Nihon Kohden Europe, Rosbach, Germany) and internationally standardized 10/20 reference EEGs as the diagnostic standard were performed in a mixed collective on a neurointensive care unit (neuro-ICU). The derivations were verified for comparability in detection of EEG background activity, epileptiform discharges, and seizure patterns. ⋯ Overall, in 89% of the patients, cEEG detected the same or additional ICU-relevant EEG patterns. The tested wireless cEEG headset is a useful monitoring tool in patients with consciousness disorders. The present study indicates that long-term measurements with the wireless eight-channel cEEG lead to a higher seizure and epileptiform discharge detection compared to intermittent 10/20 EEG derivations in the ICU setting.