Journal of clinical monitoring and computing
-
J Clin Monit Comput · Aug 2021
Heart-rate tuned comb filters for processing photoplethysmogram (PPG) signals in pulse oximetry.
Calculation of peripheral capillary oxygen saturation [Formula: see text] levels in humans is often made with a pulse oximeter, using photoplethysmography (PPG) waveforms. However, measurements of PPG waveforms are susceptible to motion noise due to subject and sensor movements. In this study, we compare two [Formula: see text]-level calculation techniques, and measure the effect of pre-filtering by a heart-rate tuned comb peak filter on their performance. ⋯ Our main conclusion is that if an uninterrupted high-quality heart rate measurement is available, then the "Red over Infrared" approach preceded by a heart-rate tuned comb filter provides the preferred trade-off between [Formula: see text]-level accuracy and computational complexity. A modest improvement in [Formula: see text] estimate accuracy at very low SNR environments may be achieved by switching to the pre-filtered DST-based algorithm (up to 6% improvement in [Formula: see text] level accuracy at -10 dB over unfiltered DST algorithm and the filtered "Red over Infrared" approach). However, this improvement comes at a significant computational cost.
-
J Clin Monit Comput · Aug 2021
Observational StudyComparing the effect of positioning on cerebral autoregulation during radical prostatectomy: a prospective observational study.
Surgery in the prolonged extreme Trendelenburg position may lead to elevated intracranial pressure and compromise cerebral hemodynamic regulation. We hypothesized that robot-assisted radical prostatectomy with head-down tilt causes impairment of cerebral autoregulation compared with open retropubic radical prostatectomy in the supine position. ⋯ Compared with open radical prostatectomy in the supine position, robot-assisted surgery in the extreme Trendelenburg position with capnoperitoneum did not lead to an impairment of cerebral autoregulation during the perioperative period in our study population.
-
J Clin Monit Comput · Aug 2021
Non-invasive assessment of respiratory muscle activity during pressure support ventilation: accuracy of end-inspiration occlusion and least square fitting methods.
Pressure support ventilation (PSV) should be titrated considering the pressure developed by the respiratory muscles (Pmusc) to prevent under- and over-assistance. The esophageal pressure (Pes) is the clinical gold standard for Pmusc assessment, but its use is limited by alleged invasiveness and complexity. The least square fitting method and the end-inspiratory occlusion method have been proposed as non-invasive alternatives for Pmusc assessment. ⋯ Both Pmusc,lsf ≤ 4 cmH2O and Pmusc,index ≤ 1 cmH2O had excellent negative predictive value [0.98 (95% CI 0.94-1) and 0.96 (95% CI 0.91-0.99), respectively)] to identify over-assistance. The inspiratory effort during PSV could not be accurately estimated by the least square fitting or end-inspiratory occlusion method because the limits of agreement were far above the signal size. These non-invasive approaches, however, could be used to screen patients at risk for absent or minimal respiratory muscles activation to prevent the ventilator-induced diaphragmatic dysfunction.
-
J Clin Monit Comput · Aug 2021
A new reliable acoustic respiratory monitoring technology during upper gastrointestinal tract therapeutic endoscopy with CO2 insufflation.
Previous studies documented the effectiveness and benefits of capnography monitoring during propofol-based sedation for colonoscopy to reduce the incidence of hypoxemia. However, the performance of capnography during longer duration endoscopic therapy of upper gastrointestinal tract cancers under CO2 insufflation it is not well known. In this study, we compare a new device with acoustic monitoring technology to standard capnography monitoring. ⋯ The ratio of unmeasurable respiratory rate by capnography was strongly correlated to the ratio of unmeasurable PETCO2 level by capnography (R2 = 0.847). There were no severe events or adverse events (grade 2 or more) during all 49 procedures. The acoustic monitoring technology provides a more reliable respiratory monitoring when compared to standard capnography during endoscopic resection of upper gastrointestinal tract cancers under CO2 insufflation, even if the procedures were prolonged and complex.
-
J Clin Monit Comput · Aug 2021
Observational StudyCardiovascular dynamics during peroral endoscopic myotomy for esophageal achalasia: a prospective observational study using non-invasive finger cuff-derived pulse wave analysis.
Peroral endoscopic myotomy (POEM) is natural orifice transluminal endoscopic surgery to treat esophageal achalasia. During POEM, cardiovascular dynamics can be impaired by capnoperitoneum, capnomediastinum, and systemic carbon dioxide accumulation. We systematically investigated changes in cardiovascular dynamics during POEM. ⋯ HR (median at baseline: 67 (60;72) bpm), CI (2.8 (2.5;3.2) L/min/m2), SVI (42 (34;51) mL/m2), and SVRI (1994 (1652; 2559) dyn × s × cm-5 × m-2) remained stable during POEM. Mixed model-derived 95% confidence limits of hemodynamic variables during POEM were 72 to 106 mmHg for MAP, 65 to 79 bpm for HR, 2.7 to 3.3 L/min/m2 for CI, 37 and 46 mL/m2 for SVI, and 1856 and 2954 dyn × s × cm-5 × m-2 for SVRI. POEM is a safe procedure with regard to cardiovascular dynamics as it does not markedly impair MAP, HR, CI, SVI, or SVRI.