Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2022
Intraoperative neurophysiological monitoring in Latin America: A bibliometric analysis.
Intraoperative Neurophysiological Monitoring (IOMM) has been used worldwide in the attempt to reduce postsurgical neurological deficits, however, most of the publications are from developed countries. There is a global bibliometric analysis of IOMN in spinal surgery, however, the contribution of Latin America (LA) is not mentioned. The aim of this study is to describe scientific productivity, patterns of publications, and thematic trends of IONM in LA. ⋯ Mexico and Brazil have led IONM publications in LA. The lower reference in publications of visual evoked potentials and brainstem auditory evoked potentials IONM modalities, could be considered in the future to boost tailored research in LA.
-
J Clin Monit Comput · Dec 2022
Blood pressure nomograms for children undergoing general anesthesia, stratified by age and anesthetic type, using data from a retrospective cohort at a tertiary pediatric center.
Reference values for non-invasive blood pressure (NIBP) are available for children undergoing general anesthesia, but have not been analyzed by type of anesthetic. This study establishes age-specific pediatric NIBP reference values, stratified by anesthetic type: inhalational anesthesia (IHA), total intravenous anesthesia (TIVA), and mostly intravenous anesthesia (MIVA, an inhalational induction followed by intravenous maintenance of anesthesia). NIBP measurements were extracted from a de-identified vital signs database for children < 19 years undergoing anesthesia between Jan/2013-Dec/2016, excluding cardiac surgery. ⋯ Mean NIBP during anesthesia increased with age, from median values of 48 mmHg (TIVA), 45 mmHg (IHA), and 41 mmHg (MIVA) in neonates, to 70 mmHg (TIVA), 68 mmHg (IHA), and 64 mmHg (MIVA) in 18-year-olds, respectively. In children < 1 year, mean NIBP values were 4 mmHg higher with TIVA than IHA (p < 0.001). These pediatric NIBP reference values contribute to ongoing debate about alarm limits based on age and anesthetic type, and may motivate prospective studies into the effects of different anesthesia regimes on vital signs.
-
J Clin Monit Comput · Dec 2022
Comment LetterBesdata Video Laryngeal Mask (BD-VLM)- a New Vision-Incorporated 3rd Generation Video Laryngeal Mask Airway : Dear editor.
Since the recent editorial 2, we were approached to evaluate another video laryngeal mask airway - the Besdata Video Laryngeal Mask (BD-VLM) TM, which has a different design concept, specifications and characteristics (Figure 1) compared to the other two.
-
J Clin Monit Comput · Dec 2022
Effect of near real-time feedback tool in the electronic medical record on protocol compliance during laparoscopic cholecystectomy: a single-center retrospective analysis.
Implementation of evidence-based medicine has proved difficult across medical fields. Leveraging the electronic medical record may improve clinician compliance to published best practices. Our hypothesis was that the use of a near real-time feedback tool would improve compliance to the protocol steps. ⋯ Individual protocol component compliance increased from 4994/8418 (59.3%) to 7669/8554 (89.7%) (p < 0.001). The near real-time feedback tool reduced the number of cases with every number of deviations (except zero) at p < 0.001. The near real-time feedback tool significantly improved protocol compliance for patients undergoing laparoscopic cholecystectomy.