Review Meta AnalysisPerformance of closed-loop systems for intravenous drug administration: a systematic review and meta-analysis of randomised controlled trials.
Closed-loop drug delivery systems are autonomous computers able to administer medication in response to changes in physiological parameters (controlled variables). While limited evidence suggested that closed-loop systems can perform better than manual drug administration in certain settings, this technology remains a research tool with an uncertain risk/benefit profile. Our aim was comparing the performance of closed-loop systems with manual intravenous drug administration in adults. ⋯ The certainty of the evidence was low or very low for most outcomes. Automatic technology may be used to improve the hemodynamic profile during noradrenaline and vasodilators administration and reduce the duration of postanaesthetic recovery. Registration: This systematic review was registered with PROSPERO (CRD42022336950) on the 7th of June 2022.
-
J Clin Monit Comput · Feb 2024
ReviewPredictor role of heart rate variability in subarachnoid hemorrhage: A systematic review.
Background- Subarachnoid hemorrhage (SAH) is one of the most devastating diseases with a high rate of morbidity and mortality. The heart rate variability (HRV) is a non-invasive method of monitoring various components of the autonomic nervous system activity that can be utilized to delineate autonomic dysfunctions associated with various physiological and pathological conditions. The reliability of HRV as a predictor of clinical outcome in aneurysmal subarachnoid hemorrhage (aSAH) is not yet well investigated in literature. ⋯ Results- This systematic review demonstrates a correlation between early changes in HRV indices (time and frequency domain) and the development of neuro-cardiogenic complications and poor neurologic outcome in patients with SAH. Conclusions- A correlation between absolute values or changes of the LF/HF ratio and neurologic and cardiovascular complications was found in multiple studies. Because of significant limitations of included studies, a large prospective study with proper handling of confounders is needed to generate high-quality recommendations regarding HRV as a predictor of post SAH complications and poor neurologic outcome.
-
J Clin Monit Comput · Feb 2024
Randomized Controlled TrialEffect of paratracheal pressure on the effectiveness of mask ventilation in obese anesthetized patients: a randomized, cross-over study.
Paratracheal pressure has been recently suggested to compress and occlude the upper esophagus at the lower left paratracheal region to prevent gastric regurgitation alternative to cricoid pressure. It also prevents gastric insufflation. The aim of this randomized cross-over study was to investigate the effectiveness of paratracheal pressure on mask ventilation in obese anesthetized paralyzed patients. ⋯ Hypoxemia did not occur in any of the patients during mask ventilation with or without paratracheal pressure. The application of paratracheal pressure significantly increased both the expiratory tidal volume and peak inspiratory pressure during face-mask ventilation with a volume-controlled mode in obese anesthetized paralyzed patients. Gastric insufflation was not evaluated in this study during mask ventilation with or without paratracheal pressure.
-
J Clin Monit Comput · Feb 2024
Observational StudyMeasurement accuracy of a microwave doppler sensor beneath the mattress as a continuous respiratory rate monitor: a method comparison study.
Non-contact continuous respiratory rate monitoring is preferred for early detection of patient deterioration. However, this technique is under development; a gold standard respiratory monitor has not been established. Therefore, this prospective observational method comparison study aimed to compare the measurement accuracy of a non-contact continuous respiratory rate monitor, a microwave Doppler sensor positioned beneath the mattress, with that of other monitors. ⋯ The microwave Doppler sensor had a small bias but relatively low precision, similar to other devices. In CEG analyses, the risk of each monitor leading to inadequate clinical decision-making was low.
-
J Clin Monit Comput · Feb 2024
Observational StudyPostoperative circadian patterns in wearable sensor measured heart rate: a prospective observational study.
This study aimed to describe the 24-hour cycle of wearable sensor-obtained heart rate in patients with deterioration-free recovery and to compare it with patients experiencing postoperative deterioration. ⋯ The postoperative diurnal rhythm of heart rate is disturbed by different types of surgery. Both groups showed recovery of diurnal rhythm but in patients following cancer surgery, both peak and nadir heart rates were higher than in the bariatric surgery group. Especially nadir heart rate was identified as a potential prognostic marker for deterioration after cancer surgery.