Journal of clinical monitoring and computing
-
J Clin Monit Comput · Aug 2024
Review Meta AnalysisIs EIT-guided positive end-expiratory pressure titration for optimizing PEEP in ARDS the white elephant in the room? A systematic review with meta-analysis and trial sequential analysis.
Electrical Impedance Tomography (EIT) is a novel real-time lung imaging technology for personalized ventilation adjustments, indicating promising results in animals and humans. The present study aimed to assess its clinical utility for improved ventilation and oxygenation compared to traditional protocols. Comprehensive electronic database screening was done until 30th November, 2023. ⋯ Our search retrieved five controlled cohort studies and two RCTs with 515 patients and overall reduced risk of mortality [RR = 0.68; 95% CI: 0.49 to 0.95; I2 = 0%], better dynamic compliance [MD = 3.46; 95% CI: 1.59 to 5.34; I2 = 0%] with no significant difference in PaO2/FiO2 ratio [MD = 6.5; 95%CI -13.86 to 26.76; I2 = 74%]. The required information size except PaO2/FiO2 was achieved for a power of 95% based on the 50% reduction in risk of mortality, 10% improved compliance as the cumulative Z-score of the said outcomes crossed the alpha spending boundary and did not dip below the inner wedge of futility. EIT-guided individualized PEEP titration is a novel modality; further well-designed studies are needed to substantiate its utility.
-
J Clin Monit Comput · Aug 2024
ReviewAlternative sensor montage for Index based EEG monitoring. A systematic review.
The main objective of this systematic review is to assess the reliability of alternative positions of processed electroencephalogram sensors for depth of anesthesia monitoring and its applicability in clinical practice. A systematic search was conducted in PubMed, Embase, Cochrane Library, Clinical trial.gov in accordance with reporting guidelines of PRISMA statement together with the following sources: Google and Google Scholar. We considered eligible prospective studies, written in the English language. ⋯ Most studies had a low risk of bias but due to lack of information in one key domain of bias (Bias due to missing data) the overall judgement would be No Information. However, there is no clear indication that the studies are at serious or critical risk of bias. Bearing in mind, the heterogeneity and small sample size of the included studies, current evidence suggests that the alternative infraorbital sensor position is the most comparable for clinical use when the standard sensor position in the forehead is not possible.
-
J Clin Monit Comput · Aug 2024
ReviewNon-invasive technology for brain monitoring: definition and meaning of the principal parameters for the International PRactice On TEChnology neuro-moniToring group (I-PROTECT).
Technologies for monitoring organ function are rapidly advancing, aiding physicians in the care of patients in both operating rooms (ORs) and intensive care units (ICUs). Some of these emerging, minimally or non-invasive technologies focus on monitoring brain function and ensuring the integrity of its physiology. Generally, the central nervous system is the least monitored system compared to others, such as the respiratory, cardiovascular, and renal systems, even though it is a primary target in most therapeutic strategies. ⋯ The clinical utility of the key parameters available in each of these tools is summarized and explained. This comprehensive review was conducted by a panel of experts who deliberated on the included topics until a consensus was reached. Images and tables are utilized to clarify and enhance the understanding of the clinical significance of non-invasive neuromonitoring devices within these medical settings.
-
J Clin Monit Comput · Aug 2024
Multicenter StudyICP wave morphology as a screening test to exclude intracranial hypertension in brain-injured patients: a non-invasive perspective.
Intracranial hypertension (IH) is a life-threating condition especially for the brain injured patient. In such cases, an external ventricular drain (EVD) or an intraparenchymal bolt are the conventional gold standard for intracranial pressure (ICPi) monitoring. However, these techniques have several limitations. ⋯ To conclude, the P2/P1 ratio of the noninvasive ICP waveform showed in this study a high Negative Predictive Value and Likelihood Ratio in different acute neurological conditions to rule out IH. As a result, this parameter may be beneficial in situations where invasive methods are not feasible or unavailable and to screen high-risk patients for potential invasive ICP monitoring. Trial registration: At clinicaltrials.gov under numbers NCT05121155 (Registered 16 November 2021-retrospectively registered) and NCT03144219 (Registered 30 September 2022-retrospectively registered).
-
J Clin Monit Comput · Aug 2024
Estimation of the transpulmonary pressure from the central venous pressure in mechanically ventilated patients.
Transpulmonary pressure (PL) calculation requires esophageal pressure (PES) as a surrogate of pleural pressure (Ppl), but its calibration is a cumbersome technique. Central venous pressure (CVP) swings may reflect tidal variations in Ppl and could be used instead of PES, but the interpretation of CVP waveforms could be difficult due to superposition of heartbeat-induced pressure changes. Thus, we developed a digital filter able to remove the cardiac noise to obtain a filtered CVP (f-CVP). ⋯ Both PLf-CVP and PLCVP correlated well with PLPES (r = 0.98, p < 0.001 vs. r = 0.94, p < 0.001), again with a lower bias in Bland Altman analysis in favor of PLf-CVP (0.15, LoA - 0.95, 1.26 cmH2O vs. 0.80, LoA - 1.51, 3.12, cmH2O). PLf-CVP discriminated high PL value with an area under the receiver operating characteristic curve 0.99 (standard deviation, SD, 0.02) (AUC difference = 0.01 [-0.024; 0.05], p = 0.48). In mechanically ventilated patients with acute respiratory failure, the digital filtered CVP estimated ΔPES and PL obtained from digital filtered CVP represented a reliable value of standard PL measured with the esophageal method and could identify patients with non-protective ventilation settings.