Journal of clinical monitoring and computing
-
J Clin Monit Comput · Apr 2024
Racial effects on masimo pulse oximetry: impact of low perfusion index.
Evaluate the SpO2-SaO2 difference between Black and White volunteer subjects having a low perfusion index (Pi) compared to those having a normal Pi. ⋯ Masimo SET® pulse oximeters with RD SET® sensors are accurate for individuals of both Black and White races when Pi is normal, as well as during conditions when Pi is low. The ARMS for all conditions studied is well within FDA standards. This study was conducted in healthy volunteers during well-controlled laboratory desaturations, and results could vary under certain challenging clinical conditions.
-
J Clin Monit Comput · Apr 2024
Observational StudyAssessment of changes in blood volume during lower body negative pressure-induced hypovolemia using bioelectrical impedance analysis.
Lower body negative Pressure (LBNP)-induced hypovolemia is simulating acute hemorrhage by sequestrating blood into lower extremities. Bioelectrical Impedance Analysis (BIA) is based on the electrical properties of biological tissues, as electrical current flows along highly conductive body tissues (such as blood). Changes in blood volume will lead to changes in bioimpedance. This study aims to study changes in upper (UL) and lower (LL) extremities bioimpedance during LBNP-induced hypovolemia. ⋯ During LBNP-induced hypovolemia, there were reciprocal changes in UL&LL bioimpedance. These changes reflected hemodynamic compensatory mechanisms to hypovolemia.
-
J Clin Monit Comput · Apr 2024
Pressure-adjusted venting eliminates start-up delays and compensates for vertical position of syringe infusion pumps used for microinfusion.
Microinfusions are commonly used for the administration of catecholamines, but start-up delays pose a problem for reliable and timely drug delivery. Recent findings show that venting of the syringe infusion pump with draining of fluid to ambient pressure before directing the flow towards the central venous catheter does not counteract start-up delays. With the aim to reduce start-up delays, this study compared fluid delivery during start-up of syringe infusion pumps without venting, with ambient pressure venting, and with central venous pressure (CVP)-adjusted venting. ⋯ At 360 s after start-up 72% to 92% of expected fluid volumes were delivered without venting, 46% to 82% with ambient pressure venting and 96% to 99% with CVP-adjusted venting. CVP-adjusted venting demonstrated consistent results across vertical pump placements (p = 0.485), whereas the other methods had significant variances (p < 0.001 for both). In conclusion, CVP-adjusted venting effectively eliminates imprecise drug delivery and start-up delays when using microinfusions.
-
Dynamic preload parameters are used to guide perioperative fluid management. However, reported cut-off values vary and the presence of a gray zone complicates clinical decision making. Measurement error, intrinsic to the calculation of pulse pressure variation (PPV) has not been studied but could contribute to this level of uncertainty. ⋯ The predicted range in reference PPV-value changes for a measured absolute change of 1% was [- 1.3%, 3.3%] and [- 1.9%, 4%] for these two methods. We showed that all methods that calculate PPV come with varying degrees of uncertainty. Accounting for bias and precision may have important implications for the interpretation of measured PPV-values or PPV-changes.
-
J Clin Monit Comput · Apr 2024
Electroencephalographic monitoring of anesthesia during surgical procedures in mice using a modified clinical monitoring system.
Monitoring brain activity and associated physiology during the administration of general anesthesia (GA) in mice is pivotal to guarantee postanesthetic health. Clinically, electroencephalogram (EEG) monitoring is a well-established method to guide GA. There are no established methods available for monitoring EEG in mice (Mus musculus) during surgery. ⋯ EEG suppression ratios and suppression durations showed strong positive correlations with the isoflurane concentrations. The electroencephalographic indices provided by the monitor did not support online monitoring of the anesthetic status. The online available suppression duration in the raw EEG signals during isoflurane anesthesia is a straight forward and reliable marker to assure safe, adequate and reproducible anesthesia protocols.