Journal of clinical monitoring and computing
-
J Clin Monit Comput · Apr 2022
Observational StudyHeart rate variability and oxygen reserve index during cardiorespiratory events in patients undergoing ophthalmic arterial chemotherapy: a prospective observational study.
Unexpected cardiorespiratory compromise has been reported during ophthalmic arterial chemotherapy in pediatric patients with retinoblastoma. Although the underlying mechanisms remain unclear, autonomic responses are presumed to contribute to these events. We hypothesized that periprocedural heart rate variability would differ between patients with and without events. ⋯ Standard deviation of normal-to-normal R-R interval, total power, and very low-frequency power domain increased during selection of the ophthalmic artery in patients with events (all adjusted p < 0.0001), without predominancy of specific autonomic nervous alterations. Oxygen reserve index was significantly lower in patients with events than those without throughout the procedure (mean difference [95% CI], - 0.19 [- 0.32 to - 0.06], p = 0.005). Enhanced compensatory autonomic regulation without specific autonomic predominancy, and reduced oxygen reserve index was observed in patients with cardiorespiratory events than in patients without events.
-
J Clin Monit Comput · Apr 2022
Randomized Controlled TrialEffects of Varying Levels of Inspiratory Assistance with Pressure Support Ventilation and Neurally Adjusted Ventilatory Assist on Driving Pressure in Patients Recovering from Hypoxemic Respiratory Failure.
Driving pressure can be readily measured during assisted modes of ventilation such as pressure support ventilation (PSV) and neurally adjusted ventilatory assist (NAVA). The present prospective randomized crossover study aimed to assess the changes in driving pressure in response to variations in the level of assistance delivered by PSV vs NAVA. ⋯ NAVA delivers better lung-protective ventilation compared to PSV in hypoxemic ARF patients.
-
J Clin Monit Comput · Apr 2022
Randomized Controlled TrialEffects of capnometry monitoring during recovery in the post-anaesthesia care unit: a randomized controlled trial in adults (CAPNOSSPI).
Continuous capnography should be used on patients admitted to post-anaesthesia care units (PACUs) with endotracheal tubes, but this monitoring is not always performed. Optimized ventilation in the PACU could be part of the global standards of practice to maintain the benefits of perioperative ventilation. The main objective was to study the rate of patients with alveolar hypoventilation before tracheal extubation or Laryngeal Mask Airway (LMA) removal upon the measurement of continuous capnography. ⋯ clinicaltrial.gov. identifier: NCT03370081.
-
J Clin Monit Comput · Apr 2022
Randomized Controlled TrialTo compare clinical versus ultrasound assessment of correct placement of ProSeal Laryngeal mask airway (PLMA): a prospective randomized study.
Extraglottic airway devices (EAD) have revolutionized the perioperative airway management. The accuracy of clinical tests to identify malposition has been questioned by recent studies where fibreoptic evaluation identified various malpositions that were undiagnosed by a clinical test. Ultrasound (USG) has evolved to guide various airway interventions. ⋯ USG is comparable to clinical tests for evaluation of the optimal placement of PLMA. However, USG has various advantages over clinical assessment as it is quick and identifies the unacceptable placement of PLMA where the tip of PLMA may not lie over the tip of the esophagus, thereby, avoiding unnecessary mucosal injury during forceful or repeated attempts for gastric drainage tube insertion. Trial registration: Clinical Trials Registry (CTRI/2017/11/010359) dated 3rd November 2017.
-
J Clin Monit Comput · Apr 2022
Non-invasive measurement of pulse pressure variation using a finger-cuff method (CNAP system): a validation study in patients having neurosurgery.
The finger-cuff system CNAP (CNSystems Medizintechnik, Graz, Austria) allows non-invasive automated measurement of pulse pressure variation (PPVCNAP). We sought to validate the PPVCNAP-algorithm and investigate the agreement between PPVCNAP and arterial catheter-derived manually calculated pulse pressure variation (PPVINV). This was a prospective method comparison study in patients having neurosurgery. PPVINV was the reference method. ⋯ Deming regression showed a slope of 0.85 (95%-CI 0.78 to 0.91) and intercept of 0.10 (95%-CI -0.34 to 0.55). The predictive agreement between PPVCNAP and PPVINV was 82% and Cohen's kappa was 0.48. The PPVCNAP-algorithm reliably calculates pulse pressure variation compared to manual offline pulse pressure variation calculation when applied on the same arterial blood pressure waveform. The absolute and predictive agreement between PPVCNAP and PPVINV are moderate.