Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2021
Randomized Controlled TrialA mathematical model for predicting intracranial pressure based on noninvasively acquired PC-MRI parameters in communicating hydrocephalus.
To develop and validate a mathematical model for predicting intracranial pressure (ICP) noninvasively using phase-contrast cine MRI (PC-MRI). We performed a retrospective analysis of PC-MRI from patients with communicating hydrocephalus (n = 138). The patients were recruited from Shenzhen Second People's Hospital between November 2017 and April 2020, and randomly allocated into training (n = 97) and independent validation (n = 41) groups. ⋯ There was no significant difference in baseline demographic characteristics between the training and independent validation groups. The accuracy of the model for predicting ICP was 0.899 in the training cohort (n = 97) and 0.861 in the independent validation cohort (n = 41). We obtained an ICP-predicting model that showed excellent performance in the noninvasive diagnosis of clinically significant communicating hydrocephalus.
-
J Clin Monit Comput · Dec 2021
Application of a benchtop colorimetric method for quantification of blood propofol levels.
Quantification of plasma propofol (2,6-diisopropylphenol) in the context of clinical anaesthesia is challenging because of the need for offline blood sample processing using specialised laboratory equipment and techniques. In this study we sought to refine a simple procedure using solid phase extraction and colorimetric analysis into a benchtop protocol for accurate blood propofol measurement. The colorimetric method based on the reaction of phenols (e.g. propofol) with Gibbs reagent was first tested in 10% methanol samples (n = 50) containing 0.5-6.0 µg/mL propofol. Subsequently, whole blood samples (n = 15) were spiked to known propofol concentrations and processed using reverse phase solid phase extraction (SPE) and colorimetric analysis. The standard deviation of the difference between known and measured propofol concentrations in the methanol samples was 0.11 µg/mL, with limits of agreement of - 0.21 to 0.22 µg/mL. For the blood-processed samples, the standard deviation of the difference between known and measured propofol concentrations was 0.09 µg/mL, with limits of agreement - 0.18 to 0.17 µg/mL. Quantification of plasma propofol with an error of less than 0.2 µg/mL is achievable with a simple and inexpensive benchtop method.
-
J Clin Monit Comput · Dec 2021
Clinical TrialPostoperative continuous non-invasive cardiac output monitoring on the ward: a feasibility study.
Postoperative hypotension is common (occurring in one third of patients) and is associated with worse clinical outcomes. The LiDCO CNAP (continuous non-invasive arterial pressure) device measures haemodynamics but has not been widely adopted in ward environments. Improved early detection of hypotension by CNAP might guide interventions to improve clinical outcomes. ⋯ There were many episodes of hypotension unmasked through continuous monitoring. Based on the advanced haemodynamic data provided it is possible that the underlying cause of a third of postoperative hypotensive episodes is vasodilation rather than hypovolaemia. Trial registry number: NCT04010058 (ClinicalTrials.gov) Date of registration: 08/07/2019.
-
J Clin Monit Comput · Dec 2021
Anaesthesia and multimodality intraoperative neuromonitoring in carotid endarterectomy. Chronological evolution and effects on intraoperative neurophysiology.
Contingency data was retrospectively collected to evaluate the historical and current ability to provide multimodality intraoperative neurophysiological monitoring during carotid endarterectomy under two conditions: total intravenous anaesthesia (TIVA) and low dose halogenated anaesthesia (SEVO). 229 patients were monitored during carotid endarterectomy procedures under general anaesthesia between 2012 and 2020. 121 Patients were monitored with SEVO at a minimum alveolar concentration less than 0.7 and 108 were monitored using TIVA, according to common anaesthetic practice standards in our hospital across the years. Multimodality IONM was established with electroencephalography, somatosensory evoked potentials and motor evoked potentials. ⋯ When using SEVO, multimodality intraoperative neurophysiological monitoring during carotid endarterectomy could mask or miss a motor isolated change in patients in spite of low dose minimum alveolar concentration and of apparently adequate electroencephalography and somatosensory evoked potentials for monitoring. Given these difficulties, we believe the chronological transfer to TIVA could have improved our ability to establish multimodality intraoperative neurophysiological monitoring during carotid endarterectomy in recent times.
-
J Clin Monit Comput · Dec 2021
Mitochondrial oxygen monitoring with COMET: verification of calibration in man and comparison with vascular occlusion tests in healthy volunteers.
Mitochondria are the primary consumers of oxygen and therefore an important location for oxygen availability and consumption measurement. A technique has been developed for mitochondrial oxygen tension (mitoPO2) measurement, incorporated in the COMET. In contrast to most textbooks, relatively high average mitoPO2 values have been reported. ⋯ The kinetics from this decline are used to mitochondrial oxygen consumption (mitoVO2). This study validates the calibration of the COMET device in humans. For mitoVO2 measurements not only blood flow cessation but application of local pressure is of great importance to clear the measurement site of oxygen-carrying erythrocytes.