Heart-rate tuned comb filters for processing photoplethysmogram (PPG) signals in pulse oximetry.
Calculation of peripheral capillary oxygen saturation [Formula: see text] levels in humans is often made with a pulse oximeter, using photoplethysmography (PPG) waveforms. However, measurements of PPG waveforms are susceptible to motion noise due to subject and sensor movements. In this study, we compare two [Formula: see text]-level calculation techniques, and measure the effect of pre-filtering by a heart-rate tuned comb peak filter on their performance. ⋯ Our main conclusion is that if an uninterrupted high-quality heart rate measurement is available, then the "Red over Infrared" approach preceded by a heart-rate tuned comb filter provides the preferred trade-off between [Formula: see text]-level accuracy and computational complexity. A modest improvement in [Formula: see text] estimate accuracy at very low SNR environments may be achieved by switching to the pre-filtered DST-based algorithm (up to 6% improvement in [Formula: see text] level accuracy at -10 dB over unfiltered DST algorithm and the filtered "Red over Infrared" approach). However, this improvement comes at a significant computational cost.
-
J Clin Monit Comput · Aug 2021
Predicting unconsciousness after propofol administration: qCON, BIS, and ALPHA band frequency power.
During anesthesia induction with propofol the level of arousal progressively decreases until reaching loss of consciousness (LOC). In addition, there is a shift of alpha activity from parieto-occipital to frontal zones, defined as anteriorization. Whilst monitoring LOC and anteriorization would be useful to improve propofol dosage and patient safety, the current devices for anesthetic depth monitoring are unable to detect these events. ⋯ Pk values for BIS and qCON were strongly predictive of frontal alpha absolute power. During anesthesia induction with propofol it is possible to identify anteriorization with BIS and qCON in the frontal and parieto-occipital regions. Both indices showed different patterns which need to be further studied.
-
J Clin Monit Comput · Aug 2021
A new reliable acoustic respiratory monitoring technology during upper gastrointestinal tract therapeutic endoscopy with CO2 insufflation.
Previous studies documented the effectiveness and benefits of capnography monitoring during propofol-based sedation for colonoscopy to reduce the incidence of hypoxemia. However, the performance of capnography during longer duration endoscopic therapy of upper gastrointestinal tract cancers under CO2 insufflation it is not well known. In this study, we compare a new device with acoustic monitoring technology to standard capnography monitoring. ⋯ The ratio of unmeasurable respiratory rate by capnography was strongly correlated to the ratio of unmeasurable PETCO2 level by capnography (R2 = 0.847). There were no severe events or adverse events (grade 2 or more) during all 49 procedures. The acoustic monitoring technology provides a more reliable respiratory monitoring when compared to standard capnography during endoscopic resection of upper gastrointestinal tract cancers under CO2 insufflation, even if the procedures were prolonged and complex.
-
J Clin Monit Comput · Aug 2021
Non-invasive assessment of respiratory muscle activity during pressure support ventilation: accuracy of end-inspiration occlusion and least square fitting methods.
Pressure support ventilation (PSV) should be titrated considering the pressure developed by the respiratory muscles (Pmusc) to prevent under- and over-assistance. The esophageal pressure (Pes) is the clinical gold standard for Pmusc assessment, but its use is limited by alleged invasiveness and complexity. The least square fitting method and the end-inspiratory occlusion method have been proposed as non-invasive alternatives for Pmusc assessment. ⋯ Both Pmusc,lsf ≤ 4 cmH2O and Pmusc,index ≤ 1 cmH2O had excellent negative predictive value [0.98 (95% CI 0.94-1) and 0.96 (95% CI 0.91-0.99), respectively)] to identify over-assistance. The inspiratory effort during PSV could not be accurately estimated by the least square fitting or end-inspiratory occlusion method because the limits of agreement were far above the signal size. These non-invasive approaches, however, could be used to screen patients at risk for absent or minimal respiratory muscles activation to prevent the ventilator-induced diaphragmatic dysfunction.
-
J Clin Monit Comput · Aug 2021
Randomized Controlled TrialComparison of haemodynamic- and electroencephalographic-monitored effects evoked by four combinations of effect-site concentrations of propofol and remifentanil, yielding a predicted tolerance to laryngoscopy of 90.
This prospective study evaluates haemodynamic and electroencephalographic effects observed when administering four combinations of effect-site concentrations of propofol (CePROP) and remifentanil (CeREMI), all yielding a single predicted probability of tolerance of laryngoscopy of 90% (PTOL = 90%) according to the Bouillon interaction model. We aimed to identify combinations of CePROP and CeREMI along a single isobole of PTOL that result in favourable hypnotic and haemodynamic conditions. This knowledge could be of advantage in the development of drug advisory monitoring technology. 80 patients (18-90 years of age, ASA I-III) were randomized into four groups and titrated towards CePROP (Schnider model, ug⋅ml-1) and CeREMI (Minto model, ng⋅ml-1) of respectively 8.6 and 1, 5.9 and 2, 3.6 and 4 and 2.0 and 8. ⋯ This study provides clinical insight on the haemodynamic and hypnotic consequences, when a model based predicted PTOL is used as a target for combined effect-site controlled target- controlled infusion of propofol and remifentanil. Heart rate and bispectral index were significantly different between groups despite a theoretical equipotency for PTOL, suggesting that each component of the anaesthetic state (immobility, analgesia, and hypnotic drug effect) should be considered as independent neurophysiological and pharmacological phenomena. However, claims of (in)accuracy of the predicted PTOL must be considered preliminary because larger numbers of observations are required for that goal.