Journal of clinical monitoring and computing
-
J Clin Monit Comput · Apr 2021
Time delay of the qCON monitor and its performance during state transitions.
We investigated the performance of the qCON index regarding its time delay for sudden changes in the anesthetic level as well as to separate responsiveness from unresponsiveness during loss and return of responsiveness (LOR and ROR). For evaluation of the time delay, we replayed relevant EEG episodes to the qCON to simulate sudden changes between the states (i) awake/sedation, (ii) adequate anesthesia, or (iii) suppression. We also replayed EEG from 40 patients during LOR and ROR to evaluate the qCON's ability to separate responsiveness from unresponsiveness. ⋯ AUC was 0.63-0.90 for LOR and 0.61-0.79 for ROR. Time delay and performance during state transitions of the qCON were similar to other monitoring systems such as bispectral index. The better performance of qCON during LOR than ROR probably reflects the sudden change in EEG activity during LOR and the more heterogeneous EEG during ROR.
-
J Clin Monit Comput · Apr 2021
Real-time estimation of mean arterial blood pressure based on photoplethysmography dicrotic notch and perfusion index. A pilot study.
Hypotension during general anesthesia is associated with poor outcome. Continuous monitoring of mean blood pressure (MAP) during anesthesia is useful and needs to be reliable and minimally invasive. Conventional cuff measurements can lead to delays due to its discontinuous nature. ⋯ MAPNAA provides the best estimates with respect to brachial cuff MAP and invasive MAP. Regular calibration allows to reduce drift over time. Beat to beat estimation of MAP during general anesthesia from the PPG appears possible with an acceptable average error.
-
J Clin Monit Comput · Apr 2021
Observational StudyPeripheral perfusion index as a predictor of failed weaning from mechanical ventilation.
We hypothesized that impairment of peripheral perfusion index (PPI) during spontaneous breathing trial (SBT) might be predictive of weaning failure. We included 44 consecutive, adult, patients, who were scheduled for weaning after at least 48 h of invasive mechanical ventilation in this prospective observational study. Weaning failure was defined as failed SBT or reintubation within 48 h of extubation. ⋯ Patients with successful weaning showed higher augmentation of PPI during the SBT compared to re-intubated patients. Failure of augmenting the PPI by 41% at the end of SBT could predict re-intubation with negative predictive value of 95%. Clinical trial identifier: NCT03974568. https://clinicaltrials.gov/ct2/show/NCT03974568?term=ahmed+hasanin&draw=3&rank=17.
-
J Clin Monit Comput · Apr 2021
Randomized Controlled TrialPhotoplethysmography-derived approximate entropy and sample entropy as measures of analgesia depth during propofol-remifentanil anesthesia.
The ability to monitor the physiological effect of the analgesic agent is of interest in clinical practice. Nonstationary changes would appear in photoplethysmography (PPG) during the analgesics-driven transition to analgesia. The present work studied the properties of nonlinear methods including approximate entropy (ApEn) and sample entropy (SampEn) derived from PPG responding to a nociceptive stimulus under various opioid concentrations. ⋯ The result showed that low Ceremi (0 and 1 ng·ml-1) could be differentiated from high Ceremi (3 and 5 ng·ml-1) by ApEn and SampEn. Depending on the coefficient employed in algorithm: ApEn with k = 0.15 yielded the largest PK value (0.875) whereas SampEn gained its largest PK of 0.867 with k = 0.2. Thus, PPG-based ApEn and SampEn with appropriate k values have the potential to offer good quantification of analgesia depth under general anesthesia.
-
J Clin Monit Comput · Apr 2021
LetterAnti-decubitus bed mattress may interfere with cerebrovascular pressure reactivity measures due to induced ICP and ABP cyclic peaks.
Severe traumatic brain injury (TBI) patients are monitored with continuous arterial blood pressure (ABP) and intracranial pressure (ICP). The pressure reactivity index (PRx) is a frequently used correlation coefficient between ABP and ICP to inform clinicians at the bedside about trends in global cerebrovascular pressure regulation status. We present an unexpected influence of cyclic anti-decubitus mattress inflations and deflations on invasive ICP, ABP and PRx calculations in our TBI patients. ⋯ In our database, 23% (9/39) of the patients show recurrent peaks in the monitoring signals. We hypothesize that these peaks are caused by (a combination) of hydrostatic change, local (cervical) compression and/or incorrect sensor zeroing due to positional changes induced by the anti-decubitus mattress. This warrants further investigation by the manufacturer and exploration of data filters.