Randomized Controlled TrialA low dose of three local anesthetic solutions for interscalene blockade tested by thermal quantitative sensory testing: a randomized controlled trial.
This randomized double-blind controlled trial compared the block characteristics of three low-dose local anesthetics at different roots in an ultrasound-guided interscalene block, using thermal quantitative sensory testing for assessing the functioning of cutaneous small nerve fibres. A total of 37 adults scheduled to undergo shoulder arthroscopy were randomized to receive 5 mL of either 0.5% levobupivacaine with and without epinephrine 1/200,000 or 0.75% ropivacaine in a single-shot interscalene block. Thermal quantitative sensory testing was performed in the C4, C5, C6 and C7 dermatomes. ⋯ A decrease in block intensity, with minimal changes in pain detection thresholds, was observed in the roots adjacent to C5, with the lowest block intensity in C7. A clinically relevant shorter duration was found with 0.75% ropivacaine compared to the other groups. Trial registration NCT 02691442.
-
J Clin Monit Comput · Apr 2019
Correction to: Is the new ASNM intraoperative neuromonitoring supervision "guideline" a trustworthy guideline? A commentary.
The article Is the new ASNM intraoperative neuromonitoring supervision "guideline" a trustworthy guideline? A commentary, written by Stanley A. Skinner, Elif Ilgaz Aydinlar, Lawrence F. Borges, Bob S. ⋯ Strommen, Andrea Szelenyi, Armando Tello, Sedat Ulkatan, Javier Urriza and Marshall Wilkinson, was originally published electronically on the publisher's internet portal (currently SpringerLink) on 05 January 2019 without open access. With the author(s)' decision to opt for Open Choice the copyright of the article changed on 30 January 2019 to © The Author(s) 2019 and the article is forthwith distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, duplication, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made. The original article has been corrected.
-
J Clin Monit Comput · Apr 2019
Comparative StudyComparison between pulse wave velocities measured using Complior and measured using Biopac.
Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed around the neck and the wrist. ⋯ Correlation values and Bland-Altman plots showed that despite the difference in PWV magnitudes obtained by the two systems the measurements did agree well. Which implies that as long as the differences in PWV magnitudes are taken into account, either system could be used to measure PWV changes over time. However, when basing diagnosis on absolute PWV values, one should be very much aware of how the PWV was measured and with what system.
-
J Clin Monit Comput · Apr 2019
Risk factors for positioning-related somatosensory evoked potential changes in 3946 spinal surgeries.
The goal of this study was to evaluate the risk factors associated with positioning-related SSEP changes (PRSC). The study investigated the association between 18 plausible risk factors and the occurrence of intraoperative PRSC. Risk factors investigated included demographic variables, comorbidities, and procedure related variables. ⋯ Three surgical situations were associated with PRSC including abnormal baselines (p < 0.001), patients in the "superman" position (p < 0.001), and patients in surgical procedures that extended over 200 min (p = 0.03). Patients with higher BMIs and who are undergoing spinal surgery longer than 200 min, with abnormal baselines, must be positioned with meticulous attention. Gender, hypertension, and smoking were also found to be risk factors from their odds ratios.
-
J Clin Monit Comput · Apr 2019
Low temperature increases capillary blood refill time following mechanical fingertip compression of healthy volunteers: prospective cohort study.
Capillary refill time has been accepted as a method to manually assess a patient's peripheral blood perfusion. Recently, temperature has been reported to affect capillary refill time and therefore temperature may interfere with accurate bedside peripheral blood perfusion evaluation. We applied a new method of analysis that uses standard hospital pulse oximetry equipment and measured blood refill time in order to test whether lowered fingertip temperature alters peripheral blood perfusion. ⋯ A generalized linear mixed-effects model revealed that lower temperature (OR 0.63 [95% CI 0.61-0.65], p < 0.001) rather than age (OR 1.00 [0.99-1.01], p = 0.395) was the independent factor most associated with increased blood refill time. Lowered fingertip temperatures significantly increase blood refill time which then returns to baseline when the fingertip is rewarmed. In our limited number of population, we did not find an association with age after the adjustment for the fingertip temperature.