Journal of clinical monitoring and computing
-
J Clin Monit Comput · Oct 2018
Observational StudyPredictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum.
Animal studies suggest that dynamic predictors remain useful in patients with pneumoperitoneum, but human data is conflicting. Our aim was to determine predictive values of pulse pressure variation (PPV) and stroke volume variation (SVV) in patients with pneumoperitoneum using LiDCORapid™ haemodynamic monitor. Standardised fluid challenges of colloid were administered to patients undergoing laparoscopic procedures, one fluid challenge per patient. ⋯ The gray zone of PPV ranged between 6.5 and 20.5% and that of SVV between 7.5 and 13%. During pneumoperitoneum, as measured by LiDCORapid™, PPV and SVV can predict fluid responsiveness, however their sensitivity is lower than the one reported in conditions without pneumoperitoneum. Trial registry number: (with the Australian New Zealand Clinical Trials Registry): ACTRN12612000456853.
-
J Clin Monit Comput · Oct 2018
Randomized Controlled Trial Retracted PublicationEffects of ultrasound-guided stellate-ganglion block on sleep and regional cerebral oxygen saturation in patients undergoing breast cancer surgery: a randomized, controlled, double-blinded trial.
Numerous factors could contribute to sleep disturbances in women with breast cancer. We hypothesized that stellate ganglion block (SGB) during surgery would preserve sleep after surgery and increase intraoperative regional cerebral oxygen saturation (rSO2) on the blocked side in patients undergoing breast cancer surgery. A randomized, double-blinded, controlled trial was conducted at the First Hospital of China Medical University from January 2016 to September 2016. ⋯ No differences in rSO2 were observed on either the left or right side of the patients in either group 50 min after anaesthesia induction. We conclude that ropivacaine-SGB combined with general anaesthesia might increase the first postoperative sleep duration without influencing the intraoperative rSO2 in female patients undergoing elective breast cancer surgery. Clinical trials.gov identifier NCT02651519.
-
J Clin Monit Comput · Oct 2018
Video-based heart rate monitoring across a range of skin pigmentations during an acute hypoxic challenge.
The robust monitoring of heart rate from the video-photoplethysmogram (video-PPG) during challenging conditions requires new analysis techniques. The work reported here extends current research in this area by applying a motion tolerant algorithm to extract high quality video-PPGs from a cohort of subjects undergoing marked heart rate changes during a hypoxic challenge, and exhibiting a full range of skin pigmentation types. High uptimes in reported video-based heart rate (HRvid) were targeted, while retaining high accuracy in the results. ⋯ The difference between the HRvid and HRp exceeded 5 and 10 bpm, for 3.59 and 0.35% of the reporting time respectively, and at no point did these differences exceed 25 bpm. Excellent agreement was found between the HRvid and HRp in a study covering the whole range of skin pigmentation types (Fitzpatrick scales I-VI), using standard room lighting and with moderate subject motion. Although promising, further work should include a larger cohort with multiple subjects per Fitzpatrick class combined with a more rigorous motion and lighting protocol.
-
J Clin Monit Comput · Oct 2018
Randomized Controlled TrialAccuracy and reliability of a subcutaneous continuous glucose monitoring device in critically ill patients.
Subcutaneous continuous glucose monitoring (CGM) may have benefits in achieving glycemic control in critically ill patients. The aim of this study was to assess the accuracy and reliability of the FreeStyle Navigator I in critically ill patients and to assess patient related factors influencing the accuracy and reliability. This study is a retrospective analysis of data from a randomized controlled trial conducted in a 20-bed mixed intensive care unit. ⋯ Furthermore, the clinical accuracy, did not meet the required standards. The reliability was satisfactory, however, in almost a quarter of the patients the realtime data display was < 95%. The accuracy was considerably and significantly lower in hyper- and hypoglycemic ranges.