Usefulness of oxygen reserve index (ORi™), a new parameter of oxygenation reserve potential, for rapid sequence induction of general anesthesia.
The oxygen reserve index (ORi™) is a new parameter for monitoring oxygen reserve noninvasively. The aim of this study was to examine the usefulness of ORi for rapid sequence induction (RSI). Twenty adult patients who were scheduled for surgical procedures under general anesthesia were enrolled. ⋯ There was an SpO2 decline of 1% or more from the peak value after propofol administration in 13 patients, and 32.5 s (IQR 18.8-51.3) before the SpO2 decrease, ORi began to decline in 10 of the 13 (77%) patients. The ORi trends enable us to predict oxygenation reduction approximately 30 s before SpO2 starts to decline. By monitoring ORi, the incidence related to hypoxemia during RSI could be reduced.
-
J Clin Monit Comput · Aug 2018
Influence of non-invasive blood pressure measurement intervals on the occurrence of intra-operative hypotension.
The American Society of Anesthesiologists Standards for Basic Monitoring recommends blood pressure (BP) measurement every 5 min. Research has shown distractions or technical factors can cause prolonged measurement intervals exceeding 5 min. We investigated the relationship between prolonged non-invasive BP (NIBP) measurement interval and the incidence of hypotension, detected post-interval. ⋯ A key finding was that the "> 10-minute AH model" indicated that age 41-80, increased co-morbidity profile, obesity and turning (repositioning) of the operative room table were significant predictors of prolonged NIBP measurement intervals (p < 0.001). While we do not suggest NIBP measurement intervals cause hypotension, intervals greater than 6 and 10 min are associated with a fourfold increase in the propensity of an undetected transition into both RH or AH. These data support current monitoring guidelines.
-
As the clinical advantages of vapor anesthesia (VA) for sedation of patients in ICU become more apparent, the ergonomics, economy and safety issues need to be better addressed. Here we describe the use of a new commercial digital in-line anesthetic vaporizer that can be attached to the inspiratory limb of a ventilator. If used with a simple, and easily assembled secondary circuit and anesthetic reflector, the circuit remains remote from the patient, the VA consumption approaches a physical minimum, VA level is controlled and monitored, and the tidal volume size is not limited.
-
Inhaled anesthetics have been utilized mostly for general anesthesia in the operating room and oftentimes for sedation and for treatment of refractory status epilepticus and status asthmaticus in the intensive care unit. These contexts in the ICU setting are related to potential for prolonged administration wherein potential organ toxicity is a concern. ⋯ High dose inhaled agents are associated with postoperative cognitive dysfunction (POCD) and other situations. However, thus far no strong indication of problematic neuro or organ toxicity has been demonstrated after prolonged use of low dose volatile anesthesia.
-
J Clin Monit Comput · Aug 2018
Comparative StudyA novel non-invasive blood pressure waveform measuring system compared to Millar applanation tonometry.
The accurate, non-invasive, measuring of the continuous arterial blood pressure waveform faces some difficulties and an innovative blood pressure measurement technology is urgently needed. However, the arterial blood pressure waveform plays an essential role in health care by providing diagnostic information and base for calculating several heart function parameters. The aim of this study is to introduce a novel non-invasive measuring system that can measure the arterial blood pressure waveform with high accuracy in comparison to an applanation tonometry system. ⋯ The average differences ([Formula: see text]) for simultaneously recorded systolic, diastolic, mean arterial and incisura pressures were: [Formula: see text], [Formula: see text], [Formula: see text] and [Formula: see text], respectively. These results satisfy the AAMI criteria. Based on our results, this new system requires further development and validation against invasive arterial blood pressure monitoring in order to prove its usefulness in patient monitoring, emergency care, and pulse diagnosis.