A numerical model of blood oxygenation during veno-venous ECMO: analysis of the interplay between blood oxygenation and its delivery parameters.
Veno-venous extracorporeal membrane oxygenation (VV-ECMO) is an important tool in the management of most severe forms of acute respiratory failure. The determinants and management of oxygen delivery in patients treated with VV-ECMO is a complex topic. The physiological principles of oxygenation on VV-ECMO are reviewed in many textbooks. ⋯ The numerical analysis of variation and interplay between each oxygenation determinants during VV-ECMO is presented in graphical form. These results corroborate all the findings of previous studies. The proposed numerical model facilitates understanding of oxygenation physiology during VV-ECMO; it can be used for a medical simulation system and for teaching the principles of oxygenation during VV-ECMO.
-
J Clin Monit Comput · Jun 2016
Review Meta AnalysisAccuracy of pleth variability index to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis.
To systemically evaluate the accuracy of pleth variability index to predict fluid responsiveness in mechanically ventilated patients. A literature search of PUBMED, OVID, CBM, CNKI and Wanfang Data for clinical studies in which the accuracy of pleth variability index to predict fluid responsiveness was performed (last update 5 April 2015). Related journals were also searched manually. ⋯ No statistical differences were found between OR subgroup and ICU subgroup in the AUC [0.89 (95 % CI 0.85-0.92) versus 0.90 (95 % CI 0.82-0.94); P = 0.97], and in the specificity [0.84 (95 % CI 0.75-0.86) vs. 0.84 (95 % CI 0.75-0.91); P = 1.00]. Sensitivity was higher in the OR subgroup than the ICU subgroup [0.84 (95 % CI 0.78-0.88) vs. 0.56 (95 % CI 0.47-0.64); P = 0.00004]. The pleth variability index has a reasonable ability to predict fluid responsiveness.
-
J Clin Monit Comput · Jun 2016
Real time noninvasive estimation of work of breathing using facemask leak-corrected tidal volume during noninvasive pressure support: validation study.
We describe a real time, noninvasive method of estimating work of breathing (esophageal balloon not required) during noninvasive pressure support (PS) that uses an artificial neural network (ANN) combined with a leak correction (LC) algorithm, programmed to ignore asynchronous breaths, that corrects for differences in inhaled and exhaled tidal volume (VT) from facemask leaks (WOBANN,LC/min). Validation studies of WOBANN,LC/min were performed. Using a dedicated and popular noninvasive ventilation ventilator (V60, Philips), in vitro studies using PS (5 and 10 cm H2O) at various inspiratory flow rate demands were simulated with a lung model. ⋯ For the in vivo study, WOBANN,LC/min and WOBPHYS/min ranged from 3 to 12 J/min and there was an excellent relationship between WOBANN,LC/breath and WOBPHYS/breath, r = 0.93, r(2) = 0.86 (p < 0.01). An ANN combined with a facemask LC algorithm provides noninvasive and valid estimates of work of breathing during noninvasive PS. WOBANN,LC/min, automatically and continuously estimated, may be useful for assessing inspiratory muscle loads and guiding noninvasive PS settings as in a decision support system to appropriately unload inspiratory muscles.
-
J Clin Monit Comput · Jun 2016
Clinical practice in perioperative monitoring in adult cardiac surgery: is there a standard of care? Results from an national survey.
This study was to investigate and define what is considered as a current clinical practice in hemodynamic monitoring and vasoactive medication use after cardiac surgery in Italy. A 33-item questionnaire was sent to all intensive care units (ICUs) admitting patients after cardiac surgery. 71 out of 92 identified centers (77.2 %) returned a completed questionnaire. Electrocardiogram, invasive blood pressure, central venous pressure, pulse oximetry, diuresis, body temperature and blood gas analysis were identified as routinely used hemodynamic monitoring, whereas advanced monitoring was performed with pulmonary artery catheter or echocardiography. ⋯ Standard, routinely used monitoring consists of ECG, SpO2, etCO2, invasive BP, CVP, diuresis, body temperature, and BGA. It also shows that there is large variability among the various Centers regarding hemodynamic monitoring of fluid therapy and inotropes administration. Further research is required to better standardize and define the indicators to improve the standards of intensive care after cardiac surgery among Italian cardiac ICUs.