Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2015
Photoplethysmography variability as an alternative approach to obtain heart rate variability information in chronic pain patient.
Heart rate variability (HRV) is a well-known method for the assessment of autonomic nervous function of the heart. Previous study suggested that pulse rate variability (PRV) determined by photoplethysmography could be used instead of HRV to more simply assess autonomic nervous function. However, most research studies included healthy subjects. ⋯ This study investigated the correlation coefficient (by Pearson correlation) and agreement (by Bland-Altman analysis) between PRV and HRV in chronic pain patients in the clinical setting. The results showed high significant correlations (p < 0.001, r > 0.86) between all the HRV and PRV parameters and good agreements (ratio < 0.1) between the parameters in terms of HR, mean RR, VLF, LF, nLF, nHF, and SD1/SD2. Our study suggests that HRV can also be reliably estimated using the photoplethysmography-based PP interval in elderly patients with chronic pain.
-
J Clin Monit Comput · Dec 2015
Comparative StudyComparison of the effects of various airway devices on hemodynamic response and QTc interval in rabbits under general anesthesia.
In this study, we aimed to compare the effects of various airway devices on QTc interval in rabbits under general anesthesia. The subjects were randomly separated into four groups: Group ETT, Group LMA, Group PLA, Group V-gel. Baseline values and hearth rate, mean arterial pressure and ECG was obtained at the 1st, 5th and 30th minutes after administration of anesthesia and placement of airway device and, QTc interval was evaluated. Difference was observed between ET group and V-gel group in the 5th minute mean arterial pressure values (p < 0.05). It was observed that QTc intervals at the 1st and 5th minute in the ET group significantly increased when compared with the other groups (p < 0.05). Again, it was observed that QTc interval of ET group at the 15th and 30th minute was longer when compared with PLA and V-gel groups (p < 0.05). It was also observed that QTc interval of LMA Group at the 5th minute after intubation significantly increased when compared with V-gel group (p < 0.05). It was observed that HR values of ETT group at the 1st, 5th and 15th minutes after intubation increased with regards to PLA and V-gel groups (p < 0.05). It was determined that the 30th minute hearth rate of ETT group was higher when compared to V-gel group (p < 0.05). ⋯ In our study we observed that V-gel Rabbit affected both hemodynamic response and QT interval less than other airway devices.
-
J Clin Monit Comput · Dec 2015
Accuracy of continuous noninvasive hemoglobin monitoring for the prediction of blood transfusions in trauma patients.
Early detection of hemorrhagic shock is required to facilitate prompt coordination of blood component therapy delivery to the bedside and to expedite performance of lifesaving interventions. Standard physical findings and vital signs are difficult to measure during the acute resuscitation stage, and these measures are often inaccurate until patients deteriorate to a state of decompensated shock. The aim of this study is to examine a severely injured trauma patient population to determine whether a noninvasive SpHb monitor can predict the need for urgent blood transfusion (universal donor or additional urgent blood transfusion) during the first 12 h of trauma patient resuscitation. ⋯ The results demonstrate that SpHb monitoring, accompanied by continuous vital signs data and adjusted for age and sex, has good accuracy for the prediction of need for transfusion; however, as an independent variable, SpHb did not enhance predictive models in comparison to use of features extracted from conventional pulse oximetry. Nor was shock index better than conventional oximetry at discriminating hemorrhaging and prediction of casualties receiving blood. In this population of trauma patients, noninvasive SpHb monitoring, including both trends and absolute values, did not enhance the ability to predict the need for blood transfusion.
-
J Clin Monit Comput · Dec 2015
Controlled Clinical TrialContinuous and noninvasive hemoglobin monitoring reduces red blood cell transfusion during neurosurgery: a prospective cohort study.
Continuous, noninvasive hemoglobin (SpHb) monitoring provides clinicians with the trending of changes in hemoglobin, which has the potential to alter red blood cell transfusion decision making. The objective of this study was to evaluate the impact of SpHb monitoring on blood transfusions in high blood loss surgery. In this prospective cohort study, eligible patients scheduled for neurosurgery were enrolled into either a Control Group or an intervention group (SpHb Group). ⋯ Compared to the Control Group, the SpHb Group had fewer units of blood transfused (1.0 vs 1.9 units for all patients; p ≤ 0.001, and 2.3 vs 3.9 units in patients receiving transfusions; p ≤ 0.0 l), fewer patients receiving >3 units (32 vs 73%; p ≤ 0.01) and a shorter time to transfusion after the need was established (9.2 ± 1.7 vs 50.2 ± 7.9 min; p ≤ 0.00 l). The absolute accuracy of SpHb was 0.0 ± 0.8 g/dL and trend accuracy yielded a coefficient of determination of 0.93. Adding SpHb monitoring to standard of care blood management resulted in decreased blood utilization in high blood loss neurosurgery, while facilitating earlier transfusions.
-
J Clin Monit Comput · Dec 2015
Comparative StudyValidation of stroke volume and cardiac output by electrical interrogation of the brachial artery in normals: assessment of strengths, limitations, and sources of error.
The goal of this study is to validate a new, continuous, noninvasive stroke volume (SV) method, known as transbrachial electrical bioimpedance velocimetry (TBEV). TBEV SV was compared to SV obtained by cardiac magnetic resonance imaging (cMRI) in normal humans devoid of clinically apparent heart disease. Thirty-two (32) volunteers were enrolled in the study. ⋯ Bland-Altman analysis of averaged pre- and post-cMRI TBEV CO versus cMRI CO yielded a mean bias of 5.01% (0.32 L min(-1)), precision of 12.85% (0.77 L min(-1)), 95% LOA of +30.20 % (+0.1.83 L min(-1)) and -20.7% (-1.19 L min(-1)) and percent error = 24.8%. Regression analysis yielded y = 0.92x + 0.78, correlation coefficient r(2) = 0.74 (r = 0.86). TBEV is a novel, noninvasive method, which provides satisfactory estimates of SV and CO in normal humans.