Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2015
Effect of wearing an N95 respirator on infrared tympanic membrane temperature measurements.
To determine the impact of wearing an N95 filtering facepiece respirator (N95 FFR) on tympanic temperature measurements. TMT measurements, with and without wearing an N95 filtering facepiece respirator (N95 FFR) were obtained at the onset and termination of 1 h of treadmill exercise in 21 subjects, and at staggered time intervals (0, 20, 40, 60 min) during combined sedentary activity and exercise of another 46 subjects, to determine any effect on TMT. A total of 877 TMT measurements were obtained that demonstrated a mean TMT increase of 0.05 °C in the first study group (p = 0.04) and a 0.19 °C decrease in the second study group (p < 0.001) with the wearing of an N95 FFR, both of which were lower than controls. Wearing an N95 FFR for 1 h, at different levels of activity, results in significantly lower TMT values than not wearing an N95 FFR, but the magnitude of the changes would likely have minimal clinical significance.
-
J Clin Monit Comput · Dec 2015
The value of Integrated Pulmonary Index (IPI) monitoring during endoscopies in children.
The Integrated Pulmonary Index (IPI) is an algorithm included in commercially available monitors that constitutes a representation of 4 parameters: EtCO2, RR, SpO2 and PR. The IPI index has been validated for adults and children older than 1 year of age. In this study we aimed to study the value of IPI monitoring during pediatric endoscopic procedures. ⋯ No differences were noted between the different procedures. IPI alerted all apnea episodes (58 events, IPI = 1) and hypoxia (26 events, IPI ≤ 3) episodes, whereas pulse oximetry captured only the hypoxia episodes (IPI sensitivity = 1, specificity 0.98, positive predictive value 0.95). Younger patient age, use of propofol alone, higher midazolam doses and presence of anesthetist are all associated with lower IPI levels.
-
J Clin Monit Comput · Dec 2015
Observational StudyTissue perfusion and oxygenation to monitor fluid responsiveness in critically ill, septic patients after initial resuscitation: a prospective observational study.
Fluid therapy after initial resuscitation in critically ill, septic patients may lead to harmful overloading and should therefore be guided by indicators of an increase in stroke volume (SV), i.e. fluid responsiveness. Our objective was to investigate whether tissue perfusion and oxygenation are able to monitor fluid responsiveness, even after initial resuscitation. Thirty-five critically ill, septic patients underwent infusion of 250 mL of colloids, after initial fluid resuscitation. ⋯ In responders to fluids, SDF-derived microcirculatory and skin perfusion and oxygenation increased, but only the increase in cardiac output, mean arterial and pulse pressure, microvascular flow index and relative Hb concentration and oxygen saturation were able to monitor a SV increase. Our proof of principle study demonstrates that non-invasively assessed tissue perfusion and oxygenation is not inferior to invasive hemodynamic measurements in monitoring fluid responsiveness. However skin reflectance spectroscopy may be more helpful than sublingual SDF.
-
J Clin Monit Comput · Dec 2015
Automatic detection of sleep apnea based on EEG detrended fluctuation analysis and support vector machine.
Sleep apnea syndrome (SAS) is prevalent in individuals and recently, there are many studies focus on using simple and efficient methods for SAS detection instead of polysomnography. However, not much work has been done on using nonlinear behavior of the electroencephalogram (EEG) signals. The purpose of this study is to find a novel and simpler method for detecting apnea patients and to quantify nonlinear characteristics of the sleep apnea. 30 min EEG scaling exponents that quantify power-law correlations were computed using detrended fluctuation analysis (DFA) and compared between six SAS and six healthy subjects during sleep. ⋯ Significant difference was found between EEG scaling exponents of the two groups (p < 0.001). SVM was used and obtained high and consistent recognition rate: average classification accuracy reached 95.1% corresponding to the sensitivity 93.2% and specificity 98.6%. DFA of EEG is an efficient and practicable method and is helpful clinically in diagnosis of sleep apnea.
-
J Clin Monit Comput · Dec 2015
A Handy EEG Electrode Set for patients suffering from altered mental state.
Although electroencephalography (EEG) is an important diagnostic tool for investigating patients with unexplained altered mental state (AMS), recording of emergency EEG is not a clinical routine. This is mainly due to the cumbersome electrode solutions. A Handy EEG Electrode Set consists of ten EEG, two EOG, two ground and two commutative reference hydrogel-coated silver wire electrodes attached to a thin polyester carrier film. ⋯ In following 12 cases, the sensitivity and specificity for detecting EEG abnormality based on the Handy EEG Electrode Set recordings were 83 and 100 %, respectively. The Handy EEG Electrode Set proved to be easy to use and to provide valuable information for the neurophysiological evaluation of a patient suffering from AMS. However, further studies with larger number of patients are warranted to clarify the true diagnostic accuracy and applicability of this approach.