An improvised pressure gauge for regional nerve blockade/anesthesia injections: an initial study.
High injection pressure is one of the warning signs of intraneural injection, with animal models suggesting pressures higher than 69 or 176 kPa as high risk, and is normally detected subjectively and inaccurately. We describe a system improvised from common clinical components that uses Boyle's law to objectively measure injection pressure. The objectives of the study were to (1) Validate our improvised pressure gauge (IPG) by comparing the injection pressure as calculated by Boyle's law against the measured pressure and (2) Use the IPG to measure the range of injection pressures by two groups of anesthetic professionals using the "syringe feel" technique. ⋯ Anesthesiologists exceeded the threshold of 69 kPa in 18 of a total of 60 attempts whereas anesthetic assistants exceeded the threshold in 30 attempts out of 60 attempts. Anesthetic assistants exerted a higher overall pressure of 80 kPa compared to 51 kPa for anesthesiologists-this was statistically significant (p = 0.027). Our improvised system is easily and rapidly assembled from common clinical equipment and shows promise as a monitor for inadvertent intraneural injection.
-
J Clin Monit Comput · Dec 2015
A substitution method to improve completeness of events documentation in anesthesia records.
AIMS are optimized to find and display data and curves about one specific intervention but is not retrospective analysis on a huge volume of interventions. Such a system present two main limitation; (1) the transactional database architecture, (2) the completeness of documentation. In order to solve the architectural problem, data warehouses were developed to propose architecture suitable for analysis. ⋯ On the other hand, we increased by 21.1% the data completeness (from 80.3 to 97.2% of the total database) for the start and the end of anesthesia events. This method seems to be efficient to replace missing "start and end of anesthesia" events. This method could also be used to replace other missing time events in this particular data warehouse as well as in other kind of data warehouses.
-
J Clin Monit Comput · Dec 2015
Effect of wearing an N95 respirator on infrared tympanic membrane temperature measurements.
To determine the impact of wearing an N95 filtering facepiece respirator (N95 FFR) on tympanic temperature measurements. TMT measurements, with and without wearing an N95 filtering facepiece respirator (N95 FFR) were obtained at the onset and termination of 1 h of treadmill exercise in 21 subjects, and at staggered time intervals (0, 20, 40, 60 min) during combined sedentary activity and exercise of another 46 subjects, to determine any effect on TMT. A total of 877 TMT measurements were obtained that demonstrated a mean TMT increase of 0.05 °C in the first study group (p = 0.04) and a 0.19 °C decrease in the second study group (p < 0.001) with the wearing of an N95 FFR, both of which were lower than controls. Wearing an N95 FFR for 1 h, at different levels of activity, results in significantly lower TMT values than not wearing an N95 FFR, but the magnitude of the changes would likely have minimal clinical significance.
-
The primary end point when treating acute shock is to restore blood circulation, mainly by reaching macrocirculatory parameters. However, even if global haemodynamic goals can be achieved, microcirculatory perfusion may remain impaired, leading to cellular hypoxia and organ damage. Interestingly, few methods are currently available to measure the adequacy of organ blood flow and tissue oxygenation. ⋯ Several technologies allow the estimation of CO2 content from different body sites: vascular, tissular (in hollow organs, mucosal or cutaneous), and airway. These tools remain poorly evaluated, and some are used but are not widely used in clinical practice. The present review clarifies the physiology of increasing tissue CO2 during hypoperfusion and underlines the specificities of the different technologies that allow bedside estimation of tissue CO2 content.
-
J Clin Monit Comput · Oct 2015
Randomized Controlled TrialChange in auditory evoked potential index and bispectral index during induction of anesthesia with anesthetic drugs.
The aim of this study was to evaluate the efficacy of the auditory evoked potential (AEP) index (aepEX) as an assessment tool for hypnosis during induction of various anesthetic drugs, and to compare its performance to that of the bispectral index (BIS). A total of 45 cases were divided into three groups based on the drugs used for anesthesia. Before anesthetic induction, BIS and AEP monitors were initiated. ⋯ The value of aepEX significantly decreased in all groups with LOR and that of BIS also decreased except of KP group. No significant difference were observed in BIS values between baseline and LOR in the KS group. The aepEX might be more useful than BIS for hypnosis monitoring during anesthetic induction, particularly when drugs such as ketamine are used.