Journal of clinical monitoring and computing
-
J Clin Monit Comput · Feb 2015
Intraoperative neurophysiological monitoring during spine surgery with total intravenous anesthesia or balanced anesthesia with 3 % desflurane.
Total intravenous anesthesia (TIVA) with propofol and opioids is frequently utilized for spinal surgery when somatosensory evoked potentials (SSEPs) and transcranial motor evoked potentials (tcMEPs) are monitored. Many anesthesiologists would prefer to utilize low dose halogenated anesthetics (e.g. 1/2 MAC). We examined our recent experience using 3% desflurane or TIVA during spine surgery to determine the impact on propofol usage and on the evoked potential responses. ⋯ The data from these cases indicates that 1/2 MAC (3%) desflurane can be used in conjunction with SSEP and tcMEP monitoring for some adult patients undergoing spine surgery. Further studies are needed to confirm the relative benefits versus negative effects of the use of desflurane and other halogenated agents for anesthesia during procedures on neurophysiological monitoring involving tcMEPs. Further studies are also needed to characterize which patients may or may not be candidates for supplementation such as those with neural dysfunction or who are opioid tolerant from chronic use.
-
J Clin Monit Comput · Feb 2015
Randomized Controlled Trial Comparative StudyComparison of an ultrasound-guided technique versus a landmark-guided technique for internal jugular vein cannulation.
Central venous cannulation is a commonly preformed procedure in many branches of medicine, particularly in anaesthesia and intensive care medicine. The purpose of this study was to compare the landmark-guided technique to the ultrasound-guided technique for internal jugular vein cannulation in cardiovascular surgery patients. One hundred cardiovascular surgery patients, of whom 65 were male and 35 were female with ages ranging from 22 to 65, who had internal jugular cannulation between December 2010-March 2011 in our clinic were investigated prospectively. ⋯ Four patients had an arterial punction [group U (n=0) and group A (n=4)] and two patients had a hematoma [group U (n=1) and group A (n=1)]. Arterial punction complication was increased significantly in landmark group (p=0.041). The findings of this study indicate that internal jugular vein catheterization guided by real-time ultrasound results in a lower access time and a lower rate of attempts.
-
J Clin Monit Comput · Feb 2015
Real-time two-dimensional and three-dimensional echocardiographic imaging of the thoracic spinal cord: a possible new window into the central neuraxis.
Transesophageal echocardiography of the spine has been difficult to perform, and high-quality images have been difficult to obtain with earlier available technology. New capabilities in hardware and software reconstruction may allow more reliable clinical data to be obtained. We describe an initial successful attempt to image the adult spinal canal, its contents, and in situ instrumentation. ⋯ Pulsed-wave Doppler determined a biphasic pattern of blood flow in the anterior spinal artery through pulse mapping of the anatomic area. New, advanced imaging hardware and software generate clinically useful imaging of the thoracic spine in 2-D and 3-D using TEE. We believe this technology holds promise for future diagnostic and therapeutic interventions in the operating room that were previously unavailable.
-
J Clin Monit Comput · Feb 2015
Capability of a neck worn device to measure sleep/wake, airway position, and differentiate benign snoring from obstructive sleep apnea.
To evaluate the accuracy of a neck-worn device in measuring sleep/wake, detecting supine airway position, and using loud snoring to screen for obstructive sleep apnea. Study A included 20 subjects who wore the neck-device during polysomnography (PSG), with 31 records obtained from diagnostic and split-night studies. Study B included 24 community-based snorers studied in-home for up to three-nights with obstructive sleep apnea (OSA) severity measured with a validated Level III recorder. ⋯ Neck actigraphy appears capable of estimating sleep/wake. The accuracy of supine airway detection with the neck-device warrants further investigation. Measurement of loud snoring appears to provide a screening tool for differentiating positional apneic and benign snorers.
-
J Clin Monit Comput · Feb 2015
Pulse oximetry-derived respiratory rate in general care floor patients.
Respiratory rate is recognized as a clinically important parameter for monitoring respiratory status on the general care floor (GCF). Currently, intermittent manual assessment of respiratory rate is the standard of care on the GCF. This technique has several clinically-relevant shortcomings, including the following: (1) it is not a continuous measurement, (2) it is prone to observer error, and (3) it is inefficient for the clinical staff. ⋯ Excellent agreement was found between RRoxi and RRETCO2, with a mean difference of -0.48 brpm and standard deviation of 1.77 brpm. These data demonstrate that our novel respiratory rate algorithm is a potentially viable method of monitoring respiratory rate in GCF patients. This technology provides the means to facilitate continuous monitoring of respiratory rate, coupled with arterial oxygen saturation and pulse rate, using a single non-invasive sensor in low acuity settings.