Capability of a neck worn device to measure sleep/wake, airway position, and differentiate benign snoring from obstructive sleep apnea.
To evaluate the accuracy of a neck-worn device in measuring sleep/wake, detecting supine airway position, and using loud snoring to screen for obstructive sleep apnea. Study A included 20 subjects who wore the neck-device during polysomnography (PSG), with 31 records obtained from diagnostic and split-night studies. Study B included 24 community-based snorers studied in-home for up to three-nights with obstructive sleep apnea (OSA) severity measured with a validated Level III recorder. ⋯ Neck actigraphy appears capable of estimating sleep/wake. The accuracy of supine airway detection with the neck-device warrants further investigation. Measurement of loud snoring appears to provide a screening tool for differentiating positional apneic and benign snorers.
-
J Clin Monit Comput · Feb 2015
Thoracic impedance measures tissue characteristics in the vicinity of the electrodes, not intervening lung water: implications for heart failure monitoring.
The rationale for intrathoracic impedance (Z) detection of worsening heart failure (HF) presupposes that changes in Z reflect changes in pulmonary congestion, but is confounded by poor specificity in clinical trials. We therefore tested the hypothesis that Z is primarily affected by tissue/water content in proximity to electrodes rather than by lung water distribution between electrodes through the use of a new computational model for deriving the near-field impedance contributions from the various electrodes. Six sheep were implanted with a left atrial pressure (LAP) monitor and a cardiac resynchronization therapy device which measured Z from six vectors comprising of five electrodes. ⋯ In contrast, during the simulated formation of device-pocket edema (induced by fluid injection) the near-field impedance of the subcutaneous electrode had an instantaneous response, while the intra-cardiac electrodes had a minimal inconsistent response. This study suggests that the primary contribution to the vector based Z is from the tissue/water in proximity to the individual electrodes. This novel finding may help explain the limited utility of Z for detecting worsening HF.
-
J Clin Monit Comput · Feb 2015
Analysis of heart rate variability during auditory stimulation periods in patients with schizophrenia.
The vulnerability-stress model is a hypothesis for symptom development in schizophrenia patients who are generally characterized by cardiac autonomic dysfunction. Therefore, measures of heart rate variability (HRV) have been widely used in schizophrenics for assessing altered cardiac autonomic regulations. The goal of this study was to analyze HRV of schizophrenia patients and healthy control subjects with exposure to auditory stimuli. ⋯ In comparison with control subjects, patients with schizophrenia exhibited lower high-frequency power and a higher low-frequency to high-frequency ratio. Moreover, while WN stimulus decreased parasympathetic activity in healthy subjects, no significant changes in heart rate and frequency-domain HRV parameters were observed between the auditory stimulation and rest periods in schizophrenia patients. We can conclude that HRV can be used as a sensitive index of emotion-related sympathetic activity in schizophrenia patients.