Journal of clinical monitoring and computing
-
J Clin Monit Comput · Feb 2015
Carbon dioxide monitoring during laparoscopic-assisted bariatric surgery in severely obese patients: transcutaneous versus end-tidal techniques.
Various factors including severe obesity or increases in intra-abdominal pressure during laparoscopy can lead to inaccuracies in end-tidal carbon dioxide (PETCO2) monitoring. The current study prospectively compares ET and transcutaneous (TC) CO2 monitoring in severely obese adolescents and young adults during laparoscopic-assisted bariatric surgery. Carbon dioxide was measured with both ET and TC devices during insufflation and laparoscopic bariatric surgery. ⋯ In the young severely obese population both TC and PETCO2 monitoring can be used to effectively estimate PaCO2. The correlation of PaCO2 to TC-CO2 is good, and similar to the correlation of PaCO2 to PETCO2. In this population, both of these non-invasive measures of PaCO2 can be used to monitor ventilation and minimize arterial blood gas sampling.
-
J Clin Monit Comput · Feb 2015
Randomized Controlled Trial Comparative StudyComparison of an ultrasound-guided technique versus a landmark-guided technique for internal jugular vein cannulation.
Central venous cannulation is a commonly preformed procedure in many branches of medicine, particularly in anaesthesia and intensive care medicine. The purpose of this study was to compare the landmark-guided technique to the ultrasound-guided technique for internal jugular vein cannulation in cardiovascular surgery patients. One hundred cardiovascular surgery patients, of whom 65 were male and 35 were female with ages ranging from 22 to 65, who had internal jugular cannulation between December 2010-March 2011 in our clinic were investigated prospectively. ⋯ Four patients had an arterial punction [group U (n=0) and group A (n=4)] and two patients had a hematoma [group U (n=1) and group A (n=1)]. Arterial punction complication was increased significantly in landmark group (p=0.041). The findings of this study indicate that internal jugular vein catheterization guided by real-time ultrasound results in a lower access time and a lower rate of attempts.
-
J Clin Monit Comput · Feb 2015
Real-time two-dimensional and three-dimensional echocardiographic imaging of the thoracic spinal cord: a possible new window into the central neuraxis.
Transesophageal echocardiography of the spine has been difficult to perform, and high-quality images have been difficult to obtain with earlier available technology. New capabilities in hardware and software reconstruction may allow more reliable clinical data to be obtained. We describe an initial successful attempt to image the adult spinal canal, its contents, and in situ instrumentation. ⋯ Pulsed-wave Doppler determined a biphasic pattern of blood flow in the anterior spinal artery through pulse mapping of the anatomic area. New, advanced imaging hardware and software generate clinically useful imaging of the thoracic spine in 2-D and 3-D using TEE. We believe this technology holds promise for future diagnostic and therapeutic interventions in the operating room that were previously unavailable.
-
J Clin Monit Comput · Feb 2015
Capability of a neck worn device to measure sleep/wake, airway position, and differentiate benign snoring from obstructive sleep apnea.
To evaluate the accuracy of a neck-worn device in measuring sleep/wake, detecting supine airway position, and using loud snoring to screen for obstructive sleep apnea. Study A included 20 subjects who wore the neck-device during polysomnography (PSG), with 31 records obtained from diagnostic and split-night studies. Study B included 24 community-based snorers studied in-home for up to three-nights with obstructive sleep apnea (OSA) severity measured with a validated Level III recorder. ⋯ Neck actigraphy appears capable of estimating sleep/wake. The accuracy of supine airway detection with the neck-device warrants further investigation. Measurement of loud snoring appears to provide a screening tool for differentiating positional apneic and benign snorers.
-
J Clin Monit Comput · Feb 2015
Pulse oximetry-derived respiratory rate in general care floor patients.
Respiratory rate is recognized as a clinically important parameter for monitoring respiratory status on the general care floor (GCF). Currently, intermittent manual assessment of respiratory rate is the standard of care on the GCF. This technique has several clinically-relevant shortcomings, including the following: (1) it is not a continuous measurement, (2) it is prone to observer error, and (3) it is inefficient for the clinical staff. ⋯ Excellent agreement was found between RRoxi and RRETCO2, with a mean difference of -0.48 brpm and standard deviation of 1.77 brpm. These data demonstrate that our novel respiratory rate algorithm is a potentially viable method of monitoring respiratory rate in GCF patients. This technology provides the means to facilitate continuous monitoring of respiratory rate, coupled with arterial oxygen saturation and pulse rate, using a single non-invasive sensor in low acuity settings.