Journal of clinical monitoring and computing
-
J Clin Monit Comput · Apr 2023
Letter Case ReportsPeri-operative multimodal monitoring: a real need or a luxury?
The present case of a patient with several co-morbidities undergoing complex vitrectomy under peribulbar block and sedation with Target Controlled Infusion (TCI of propofol and dexmedetomidine with EEG and Analgesia Nociception Index (ANI) monitoring illustrates the benefits of multimodal monitoring to differentiate the effect of hypnotic and antinociceptive drugs. It is highlighted the delta-alpha electroencephalographic pattern showing adequate sedation, the beta arousal pattern in the EEG concommitant to decrease in the ANI translating insufficient anti-nociception.
-
J Clin Monit Comput · Apr 2023
Quantitative relationship between anteriorization of alpha oscillations and level of general anesthesia.
A typical electroencephalogram (EEG) change induced by general anesthesia is anteriorization-disappearance of occipital alpha oscillations followed by the development of frontal alpha oscillations. Investigating the quantitative relationship between such a specific EEG change and the level of anesthesia has academic and clinical importance. We quantified the degree of anteriorization and investigated its detailed relationship with the level of anesthesia. ⋯ The change in [Formula: see text] and [Formula: see text] with BIS value showed different patterns by the type of anesthetic agent, whereas that in [Formula: see text] was more consistent with smaller individual variance. Anteriorization, quantified by the difference between frontal and occipital alpha powers, continuously developed in conjunction with general anesthesia. Quantifying anteriorization may provide an objective indicator of the level of anesthesia.
-
J Clin Monit Comput · Apr 2023
Observational StudyBioimpedance spectroscopy fluid analysis in acute high-risk abdominal surgery, a prospective clinician-blinded observational feasibility study.
Objective assessment of fluid status in critical surgical care may help optimize perioperative fluid administration and prevent postoperative fluid retention. We evaluated the feasibility of hydration status and fluid distribution assessment by Bioimpedance spectroscopy Analysis (BIA) in patients undergoing acute high-risk abdominal (AHA) surgery. This observational study included 73 patients undergoing AHA surgery. ⋯ Perioperative overhydration measured with BIA was associated with worse outcome compared to patients with normo- or dehydration. We have demonstrated the feasibility of obtaining perioperative bedside BIA measurements in patients undergoing AHA surgery. BIA measurements correlated with fluid balance, weight changes, and postoperative clinical complications. BIA-assessed fluid status might add helpful information to guide fluid management in patients undergoing AHA surgery.
-
J Clin Monit Comput · Apr 2023
Effect of quantitative versus qualitative neuromuscular blockade monitoring on rocuronium consumption in patients undergoing abdominal and gynecological surgery: a retrospective cohort study.
The level of neuromuscular blockade can be assessed by subjective (qualitative) and objective (quantitative) methods. This study aims to compare the dosage of the neuromuscular blocking agents (NMBA) rocuronium and the need for reversion by sugammadex between those methods. A retrospective, observational analysis was conducted. ⋯ Significantly fewer patients in the quantitative NMM-group required oxygen-supply postoperative (quantitative NMM: 43% (n = 120)) vs. tactile NMM: 57% (n = 128)) (p = 0.002). The use of quantitative assessment of NMBA results in a lower overall dosage and requires fewer repetitions of rocuronium application. Therefore, quantitative monitoring systems should be used to monitor NMBA intraoperatively to reduce NMBA dosing, while achieving continuous neuromuscular blockade.
-
J Clin Monit Comput · Apr 2023
Observational StudyAssessing a novel second generation laryngeal mask airway using the 'ADEPT' approach: results from the LMA® Protector™ observational study.
To address the problem of lack of clinical evidence for airway devices introduced to the market, the Difficult Airway Society (UK) developed an approach (termed ADEPT; Airway Device Evaluation Project Team) to standardise the model for device evaluation. Under this framework we assessed the LMA Protector, a second generation laryngeal mask airway. A total of 111 sequential adult patients were recruited and the LMA Protector inserted after induction of general anaesthesia. ⋯ However, the first time insertion rate failure was 9.9% (95% CI 5.1-17.0%). There were no episodes of patient harm recorded, particularly desaturation. The LMA Protector appears suitable for clinical use, but an accompanying article discusses our reflections on the ADEPT approach to studying airway devices from a strategic perspective.