Journal of clinical monitoring and computing
-
J Clin Monit Comput · Feb 2023
Randomized Controlled TrialComparing the effects of continuous positive airway pressure via mask or helmet interface on oxygenation and pulmonary complications after major abdominal surgery: a randomized trial.
The risk of pulmonary complications is high after major abdominal surgery but may be reduced by prophylactic postoperative noninvasive ventilation using continuous positive airway pressure (CPAP). This study compared the effects of intermittent mask CPAP (ICPAP) and continuous helmet CPAP (HCPAP) on oxygenation and the risk of pulmonary complications following major abdominal surgery. Patients undergoing open abdominal aortic aneurysm repair or pancreaticoduodenectomy were randomized (1:1) to either postoperative ICPAP or HCPAP. ⋯ Comfort scores were similar in both groups (p = 0.43), although a sensation of claustrophobia during treatment was only experienced in the HCPAP group (11% vs. 0%, p = 0.03). Compared with ICPAP, using HCPAP was associated with similar oxygenation (i.e., PaO2/FIO2 ratio) and a similar risk of pulmonary complications. However, HCPAP treatment was associated with a higher sensation of claustrophobia.
-
J Clin Monit Comput · Feb 2023
The impact of urine flow on urine oxygen partial pressure monitoring during cardiac surgery.
Urine oxygen partial pressure (PuO2) may be useful for assessing acute kidney injury (AKI) risk. The primary purpose of this study was to quantify the ability of a novel urinary oxygen monitoring system to make real-time PuO2 measurements intraoperatively which depends on adequate urine flow. We hypothesized that PuO2 data could be acquired with enough temporal resolution to provide real-time information in both AKI and non-AKI patients. ⋯ NCT03335865, First Posted Date: Nov. 8th, 2017.
-
J Clin Monit Comput · Feb 2023
Pulmonary gas exchange evaluated by machine learning: a computer simulation.
Using computer simulation we investigated whether machine learning (ML) analysis of selected ICU monitoring data can quantify pulmonary gas exchange in multi-compartment format. A 21 compartment ventilation/perfusion (V/Q) model of pulmonary blood flow processed 34,551 combinations of cardiac output, hemoglobin concentration, standard P50, base excess, VO2 and VCO2 plus three model-defining parameters: shunt, log SD and mean V/Q. From these inputs the model produced paired arterial blood gases, first with the inspired O2 fraction (FiO2) adjusted to arterial saturation (SaO2) = 0.90, and second with FiO2 increased by 0.1. 'Stacked regressor' ML ensembles were trained/validated on 90% of this dataset. ⋯ Single-point estimates were less accurate: R2 = 0.77-0.89, slope = 0.991-0.993, intercept = 0.009-0.334. ML applications using blood gas, indirect calorimetry, and cardiac output data can quantify pulmonary gas exchange in terms describing a 20 compartment V/Q model of pulmonary blood flow. High fidelity reports require data from two FiO2 settings.
-
J Clin Monit Comput · Feb 2023
Sublingual microcirculation: comparison between the 415 nm blue light and 520 nm green light of sidestream dark field videomicroscopes.
Green light with a wavelength of 520 nm is commonly used in sidestream dark field (SDF) video microscopes for sublingual microcirculation assessment in clinical practice. However, blue light could obtain a clearer microcirculatory image due to a higher light absorption coefficient of hemoglobin. The aim of this study was to compare the sublingual microcirculatory image quality acquisition and related microcirculatory parameters between 520 nm green light and 415 nm blue light probes in the SDF device named MicroSee V100. ⋯ Compared to green light, an increase in the perfused vessel density (paired t test, increased by 4.6 ± 4.7 mm/mm2, P < 0.0001) and total vessel density (paired t test, increased by 5.1 ± 4.6 mm/mm2, P < 0.0001) was observed by blue light in the healthy volunteers. The blue light probe had a significantly lower rate of unacceptable films than the green light probe in the 200 films of ICU patients (10/100 vs. 39/100, P < 0.0001). Blue light provides a higher microcirculatory vessel density and image quality than the existing SDF probe using green light.