Journal of clinical monitoring and computing
-
J Clin Monit Comput · Feb 2023
Observational StudyPeak systolic myocardial velocity in patients undergoing surgical aortic valve replacement for severe aortic stenosis: prognostic value and natural course.
Myocardial systolic longitudinal function has been known to decrease in patients with severe aortic stenosis (AS). Preoperative peak systolic myocardial velocity at the septal mitral valve annulus (S'), measured using Doppler tissue imaging, was used as an indicator for myocardial systolic longitudinal function. The prognostic value and natural course of S' after surgical aortic valve replacement for severe AS have not been elucidated. ⋯ The difference in pre-S' level maintained over time, and remained consistent in the adjusted analysis. Pre-S' < 5.4 cm/s was found to be associated with an increased long-term all-cause mortality. In addition, the trajectories for post-S' were different according to pre-S', which remained after adjustment.
-
J Clin Monit Comput · Feb 2023
A novel smartphone app for blood pressure measurement: a proof-of-concept study against an arterial catheter.
Smartphones may provide a highly available access to simplified hypertension screening in environments with limited health care resources. Most studies involving smartphone blood pressure (BP) apps have focused on validation in static conditions without taking into account intraindividual BP variations. We report here the first experimental evidence of smartphone-derived BP estimation compared to an arterial catheter in a highly dynamic context such as induction of general anesthesia. ⋯ To the best of our knowledge, this is the first time a smartphone app was compared to an invasive BP reference. Its trending ability was investigated in highly dynamic conditions, demonstrating high concordance and accuracy. Our study could lead the way for mobile devices to leverage the measurement of BP and management of hypertension.
-
J Clin Monit Comput · Feb 2023
Arterial to end-tidal CO2 gradients during isocapnic hyperventilation.
Isocapnic hyperventilation (ICHV) is occasionally used to maintain the end-expired CO2 partial pressure (PETCO2) when the inspired CO2 (PICO2) rises. Whether maintaining PETCO2 with ICHV during an increase of the PICO2 also maintains arterial PCO2 (PaCO2) remains poorly documented. 12 ASA PS I-II subjects undergoing a robot-assisted radical prostatectomy (RARP) (n = 11) or cystectomy (n = 1) under general endotracheal anesthesia with sevoflurane in O2/air (40% inspired O2) were enrolled. PICO2 was sequentially increased from 0 to 0.5, 1.0, 1.5 and 2% by adding CO2 to the inspiratory limb of the circle system, while increasing ventilation to a target PETCO2 of 4.7-4.9% by adjusting respiratory rate during controlled mechanical ventilation. ⋯ Pa-ETCO2 gradients did not change when PICO2 increased. The effect of a modest rise of PICO2 up to 1.5% on PETCO2 during RARP can be readily overcome by increasing ventilation without altering the Pa-ETCO2 gradients. At higher PICO2, airway pressures may become a limiting factor, which requires further study.
-
J Clin Monit Comput · Feb 2023
Unexpected median SEPs fluctuations during brain cavernous malformation resection with no post-operative deficit.
Median nerve somatosensory evoked potentials (SEPs) may present changes during cavernous malformation (CM) resection unrelated to new post-operative sensory deficits. We performed intraoperative neurophysiological monitoring of median SEPs (m-SEPs) in three patients who underwent CM resection (surgery) near the sensory-motor cortex. The only preoperative clinical manifestations in all patients were seizures. ⋯ None of these patients developed new post-operative clinical deficits. During brain cavernous malformation resection, significant fluctuations in the amplitude of different components of m-SEPs may occur. These changes may be due to excitability variations on m-SEP generators and do not translate into new post-operative neurological deficits.
-
J Clin Monit Comput · Feb 2023
Is it feasible to measure intra-abdominal pressure using a balloon-tipped rectal catheter? Results of a validation study.
The gold standard to measure intra-abdominal pressure (IAP) is intra-vesical measurement via the urinary bladder. However, this technique is restricted in ambulatory settings because of the risk of iatrogenic urinary tract infections. Rectal IAP measurements (IAPrect) may overcome these limitations, but requires validation. ⋯ Repeatability of IAPrect was not reliable (R = 0.539, p = 0.315). For both techniques, measurements with the external abdominal pressure belt were significantly higher compared to those without (p < 0.03). IAPrect has important shortcomings making IAP estimation using a rectal catheter unfeasible because the numbers cannot be trusted nor validated.