Comment LetterBesdata Video Laryngeal Mask (BD-VLM)- a New Vision-Incorporated 3rd Generation Video Laryngeal Mask Airway : Dear editor.
Since the recent editorial 2, we were approached to evaluate another video laryngeal mask airway - the Besdata Video Laryngeal Mask (BD-VLM) TM, which has a different design concept, specifications and characteristics (Figure 1) compared to the other two.
-
J Clin Monit Comput · Dec 2022
Prospective validation of gas man simulations of sevoflurane in O2/air over a wide fresh gas flow range.
The use of inhaled anesthetics has come under increased scrutiny because of their environmental effects. This has led to a shift where sevoflurane in O2/air has become the predominant gas mixture to maintain anesthesia. To further reduce environmental impact, lower fresh gas flows (FGF) should be used. ⋯ During the first 15 min, MDPE and MDAPE were 7% [- 6, 28] and 13% [6, 32], respectively, and during the last 45 min - 1% [- 5, 5] and 5% [2, 9], respectively. In conclusion, Gas Man® predicts FETsevo in O2/air in adults over a wide range of FGF and vaporizer settings using different workstations with both MDPE and MDAPE < 10% during the first hour of anesthesia, with better relative performance for simulating maintenance than wash-in. In the authors' opinion, this degree of performance suffices for Gas Man® to be used to quantify the environmental impact of FGF reduction in real life practice of the wash-in and maintenance period combined.
-
J Clin Monit Comput · Dec 2022
Improvement in vocal-cord visualization with Trachway video intubating stylet using direct oxygen flow and effective analysis of the fraction of inspired oxygen: a bench study.
The Trachway video intubating stylet device facilitates the visualization of the airways of patients from the tip of an endotracheal tube (ETT) during intubation. The major limitations of Trachway are the restricted view due to secretions and the risk of a prolonged apnea during intubation. We conducted a bench study to verify the performance of an alternative, easily applicable airway device that allows better visualization of trackways during Trachway-assisted intubation and prevents the detrimental effects of apnea-related hypoxia. ⋯ The ODD, which can be easily coupled with Trachway stylets, enabled high-quality visualization during oxygen flows of 6-8 L/min, and higher FiO2 fractions were achieved at higher oxygen flow rates. The use of the ODD improved the visualization of the airways during video stylet-assisted intubations using the additional FiO2 supply. The ODD developed in this study improves the visualization of airways with Trachway stylets and enhances the safety of intubation.
-
J Clin Monit Comput · Dec 2022
Accuracy of a point-of-care blood lactate measurement device in a prehospital setting.
Point-of-care blood lactate is a promising prognostic biomarker of short-term mortality risk. Portable lactate meters need validation in the prehospital setting before widespread implementation and it is unknown whether the mode of sampling (arterial, capillary or venous) matters. This study aims to compare the StatStrip Xpress Lactate Meter's (SSX) accuracy to a validated blood gas analyser, ABL90 FLEX (ABL90), in arterial samples in the prehospital environment and to determine if lactate levels measured in venous and capillary blood samples are sufficiently accurate compared to arterial lactate levels. ⋯ Bland-Altman plots showed that SSX lactate measurements in arterial, venous and capillary blood samples all had systematically negative biases compared to ABL90. We conclude that the SSX is accurate in our prehospital setting. Venous samples should be preferred over capillary samples, when arterial samples cannot be obtained.
-
J Clin Monit Comput · Dec 2022
Validity of transcranial Doppler ultrasonography-determined dynamic cerebral autoregulation estimated using transfer function analysis.
Transcranial Doppler ultrasonography (TCD) is used widely to evaluate dynamic cerebral autoregulation (dCA). However, the validity of TCD-determined dCA remains unknown because TCD is only capable of measuring blood velocity and thus only provides an index as opposed to true blood flow. To test the validity of TCD-determined dCA, in nine healthy subjects, dCA was evaluated by transfer function analysis (TFA) using cerebral blood flow (CBF) or TCD-measured cerebral blood velocity during a perturbation that induces reductions in TCD-determined dCA, lower body negative pressure (LBNP) at two different stages: LBNP - 15 mmHg and - 50 mmHg. ⋯ In addition, the ICA Q-determined TFA LF ngain from rest to LBNP50 was significantly correlated with TCD-determined TFA LF ngain (r = 0.460, P = 0.016) despite a low intraclass correlation coefficient. Moreover, in the Bland-Altman analysis, the difference in the TFA LF ngains determined by blood flow and velocity was within the margin of error, indicating that the two measurement methods can be interpreted as equivalent. These findings suggest that TCD-determined dCA can be representative of actual dCA evaluated with CBF.