Journal of clinical monitoring and computing
-
J Clin Monit Comput · Aug 2022
Randomized Controlled Trial Multicenter StudyPharmacodynamic analysis of a fluid challenge with 4 ml kg-1 over 10 or 20 min: a multicenter cross-over randomized clinical trial.
A number of studies performed in the operating room evaluated the hemodynamic effects of the fluid challenge (FC), solely considering the effect before and after the infusion. Few studies have investigated the pharmacodynamic effect of the FC on hemodynamic flow and pressure variables. We designed this trial aiming at describing the pharmacodynamic profile of two different FC infusion times, of a fixed dose of 4 ml kg-1. ⋯ The infusion time of FC administration affects fluid responsiveness, being higher for FC10 as compared to FC20. The effect on flow variables of either FCs fades 5 min after the end of infusion.
-
J Clin Monit Comput · Aug 2022
Vigilance: the behavioral impact of quantitative monitoring on administration and antagonism of neuromuscular blocking agents.
The aim of this study was to determine whether use of acceleromyography (1) changes dosing of neuromuscular blocking agents (NMBAs), and (2) increases the time between neostigmine administration and extubation, when compared with subjective assessment of neuromuscular blockade. ⋯ The data presented provides insight about the behavioral engineering inherent to the practice of anesthesiology. Introduction of neuromuscular blockade assessment appeared to increase provider vigilance in dosing of NMBAs-regardless of assessment method. The frequency of intraoperative monitoring (quantitative or subjective) was associated with an increased total dose of NMBA administered and decreased time interval between the last dose of neostigmine and extubation.
-
J Clin Monit Comput · Aug 2022
Correlation between brain tissue oxygen tension and regional cerebral oximetry in uninjured human brain under conditions of changing ventilation strategy.
Controversy surrounds regional cerebral oximetry (rSO2) because extracranial contamination and unmeasured changes in cerebral arterial:venous ratio confound readings. Correlation of rSO2 with brain tissue oxygen (PbrO2), a "gold standard" for cerebral oxygenation, could help resolve this controversy but PbrO2 measurement is highly invasive. This was a prospective cohort study. ⋯ From set point 1 to set point 2, PbrO2 increased from median 6.0, IQR 4.0-11.3 to median 22.5, IQR 9.8-43.6, p = 0.015; rSO2 increased from median 68.0, IQR 62.5-80.5 to median 83.0, IQR 74.0-90.0, p = 0.047. Correlation between PbrO2 and rSO2 is evident. Increasing FiO2 and PaCO2 results in significant increases in cerebral oxygenation measured by both monitors.
-
J Clin Monit Comput · Aug 2022
Laboratory evaluation of performance of pulse oximeters from six different manufacturers during motion artifacts produced by Fluke 2XL SpO2 simulator.
We performed laboratory evaluation of six pulse oximeters from different manufacturers using the Fluke 2XL SpO2 simulator. The pulse oximeter probes were labeled 1 through 6 and tested using the two pre-programed preset functions of the Fluke 2XL SpO2 simulator, level 01 and level 02, for their performance in the presence of motion artifacts. The pulse oximeters were also tested at low perfusion index (PI) settings. ⋯ When probes were attached directly in the presence of motion artifacts, probes 2 and 6 performed well, whereas all other probes performed poorly. Successively lowering the PI degraded performance of probes 3, 4, and 5 at extremely low PI. It is observed that during motion and/or low PI conditions, multiple probes see deterioration in performance.
-
J Clin Monit Comput · Aug 2022
Observational StudyAssessment of different computing methods of inspiratory transpulmonary pressure in patients with multiple mechanical problems.
While plateau airway pressure alone is an unreliable estimate of lung overdistension inspiratory transpulmonary pressure (PL) is an important parameter to reflect it in patients with ARDS and there is no concensus about which computation method should be used to calculate it. Recent studies suggest that different formulas may lead to different tidal volume and PEEP settings. The aim of this study is to compare 3 different inspiratory PL measurement method; direct measurement (PLD), elastance derived (PLE) and release derived (PLR) methods in patients with multiple mechanical abnormalities. 34 patients were included in this prospective observational study. ⋯ There was a good aggreement and there was no bias between the measurements in Bland-Altman analysis. The estimated bias was similar between the PLD and PLE (- 3.12 ± 11 cmH2O) and PLE and PLR (3.9 ± 10.9 cmH2O) measurements. Our results suggest that standardization of calculation method of inspiratory PL is necessary before using it routinely to estimate alveolar overdistension.